SYSTEM PROGRAMMING

OVERVIEW OF SYSTEM CODE PROGRAMMING

1. There are TWO levels of codes for the 931 EntryCheck

 system. 

a.

The Master Code (used to open the door and for programming User Codes)

b.

User Codes (used by personnel to open the door)

2. All codes must be 3 to 8 digits.

3. All codes must be different from each other.

4.  5-Pad Keypads have two digits on each pad.  The system reads these numbers as the same.
     For example: 1-3-5-7-9 is the same as 2-4-6-8-0.

5.  Do not program codes, which are part of other codes.
     For example: User Code 1            1-2-3-4-5 and User Code 2             1-2-3

6. During programming, the system resets after 5 seconds if a number is not entered.  Do not let more than 5 

seconds elapse between entries or the system will reset and you will have to start over.

OVERVIEW OF THE MASTER CODE

Knowledge of the Master Code is the highest privilege granted to a user of the 931 EntryCheck

 system.  There is 

only one master code, which is used to program each of the 5 User Codes.  The factory default Master Code, 
“1-3-5-7-9”, can be used for initial programming but should be changed to a unique 3 to 8 digit code. 

The Master Code can be configured to activate either Relay #1 or Relay #2 depending on how the system hardware 
is set up (Setting Relay Options pgs 8-9).  However, the Master Code cannot be configured to Latch either relay.  

PROGRAMMING THE MASTER CODE

To Program/Change the Master Code:

1.  Select a 3 to 8 digit code that will be used for the Master Code.

     ___ ___ ___ ___ ___ ___ ___ ___

2.  Locate the Control Module, remove the cover and locate the “PROGRAM” switch on the circuit board.

3.  Press the PROGRAM switch once. (The Keypad will beep rapidly 4 times)  Once the PROGRAM switch has 

been pressed, you have 2 minutes to begin programming.

4.  At the Keypad, enter 1-1-1-9 to open the memory (you will hear three rapid beeps) and immediately enter your 

new Master code.  (Do not let more than five seconds elapse between entries or the system will reset!!!)

5.  After entering your new code, wait five seconds for the 3 reset beeps.

P:\INSTALLATION INST\Access Control\INST-931.vsd     0505     Page 10

OVERVIEW OF USER CODES

There are a total of 5 User codes (also called Secondary Codes) that can be programmed into the 931 EntryCheck

.  

User Codes can vary in length from 3 to 8 digits.  Each User Code is programmed into one of 5 User Locations. 
These Locations are as follows:

User #

User Location

User Code 1    

      1-1-1

User Code 2     

      1-1-3

User Code 3     

      1-1-5

User Code 4      

      1-1-7

User Code 5      

      1-1-9

Once a User Code has been programmed into a User Location, the User Code can be easily changed or deleted 
from the system.  

Latching and User Code Unlocking Authorization is determined by how each relay is configured. (Setting Relay 
Options pgs 8-9)

Summary of Contents for EntryCheck 931-KP-2U

Page 1: ...ryCheck The 931 EntryCheck is an easy to program easy to use stand alone self contained system with features suitable for basic access control requirements Providing either a voltage output or dry con...

Page 2: ...NG THE LOCKING DEVICE 7 BATTERY BACK UP 7 SYSTEM HARDWARE SETUP 8 REMOTE BY PASS 8 ANTI TAILGATING 8 SETTING RELAY OPTIONS 8 9 TAMPER ALARM LOCKOUT 9 SYSTEM PROGRAMMING 10 OVERVIEW OF SYSTEM CODE PROG...

Page 3: ...Length 6 Codes 1 Master 5 User of User Codes 1 3 5 7 9 Default Master Code 25 Incorrect Key Presses Tamper Alarm Non Volatile Memory Access Code Protection 40 C to 70 C 40 F to 160 F 100 Relative Humi...

Page 4: ...e configured to perform one of many different functions depending on the specific access control requirement User Authorization to control each relay is determined by Setting Relay Options see System...

Page 5: ...ble may be spliced The maximum distance between the Keypad and the Control Module must not exceed 1 000 feet For runs over 200 feet 18 gauge wire should be used Under 200 feet 20 gauge is acceptable 4...

Page 6: ...25mm drill bit 3 Place the connector on the back of the keypad in the large hole Mark the keypad mounting holes 4 Drill clearance holes in accordance with fastening method used If mounting to wood dri...

Page 7: ...ch system are two MOV s metal oxide varistor The function of the MOV is to absorb any inductive kickback from the locking device protecting the circuit board The MOV s have been installed under the re...

Page 8: ...p the MONITOR screw terminals with factory installed wire SETTING RELAY OPTIONS The 931 provides a variety of options for configuring both relays These options include User Unlock Authorization Latchi...

Page 9: ...Authorization relay for that particular User Group will energize and remain energized until a valid code followed by 7 is entered again Ex Latching Authorization P INSTALLATION INST Access Control INS...

Page 10: ...9 However the Master Code cannot be configured to Latch either relay PROGRAMMING THE MASTER CODE To Program Change the Master Code 1 Select a 3 to 8 digit code that will be used for the Master Code _...

Page 11: ...for every one second increment and 5 s for every five second increment that equal your desired Door Open Time Each valid key press a 1 or a 5 will generate a double beep Do not let more than five sec...

Page 12: ...and you will have to start over For an existing Installation There are typically two reasons for code loss static or inductive kickback There is no way to determine if the system has been affected by...

Page 13: ...APPENDIX A CIRCUIT BOARD LAYOUT P INSTALLATION INST Access Control INST 931 vsd 0505 Page 13...

Page 14: ...r relay to eliminate chatter Fail Secure Lock Fail Safe Lock Controlled by KE 265 Controlled by KE 265 CCTV DOORBELL and Fail Secure Lock Garage Door Gate Drive Controlled by KE 265 Controlled by KE 2...

Page 15: ..._________ Master Code 2 User Name__________________________ Master Code 3 User Name__________________________ Master Code 4 User Name__________________________ Master Code 5 P INSTALLATION INST Access...

Reviews: