![background image](http://html1.mh-extra.com/html/scs-sentinel/mco0063/mco0063_installation-and-user-manual_1219946032.webp)
32
EN
Appuyer
1~3 Sec
Appuyer
3 Sec
Appuyer
1
2
3
4
5
6
LED1
LED2
LED3
ON
OFF
ON
OFF
Appuyer
3 secondes
1
2
14
LED1
LED2
LED3
(2)To reset factory settings.
Press UP and DOWN for 3 seconds, and the LED display shows « CL ».
If your gate is opening when you start the programmation, stop the program to push on SET. L» appears on the
display, wait for it to turn off then go on the program 1 to reverse the rotation direction of your gate (see following
page).
LED Display
Programmable functions
« -L » : the system learning is not done
« OP » : the system is in normal operation
To program, press SET button for 3 seconds. When the LED display changes from «
OP » to « 1 », press UP or DOWN to change the function settings (1 to P). Then press
SET to enter the sub function within each group, press UP or DOWN to select sub
functions and press SET to valid
« LE » : Enter the learning mode and then wait for learning instructions.
« LP » : the system learning is in process.
The auto-learning process of gate moving :
«Gate open to the end - stop close to the end - stop»
« CL » : Reset factory setting.
Appuyer
1~3 Sec
Appuyer
3 Sec
Appuyer
1
2
3
4
5
6
LED1
LED2
LED3
ON
OFF
ON
OFF
Appuyer
3 secondes
1
2
14
LED1
LED2
LED3
Push
Push 3
sec
Push 1-3
sec
Push 1-3
sec
D3- Programmable function settings
To enter in the settings, maintain the button SET 5 seconds. A «1» appears. Scroll with UP or DOWN until the
wanted function, then SET to enter in this function. Then, modify the value with UP or DOWN (Be carefull, if no
button is pressed for 5 seconds, the display goes out of the automatic settings mode).
Summary of Contents for MCO0063
Page 9: ...9 FR a b d C5 Installation et raccordement Branchement de l alimentation 230 volts...
Page 28: ...28 EN a b d C5 Installing 230V connection switch power supply...
Page 45: ...45 IT a d C5 Impianto Collegamento dell alimentazione 230 volt...
Page 63: ...ES 63 a b d C5 Instalaci n y conexi n Cableado de la alimentaci n 230 volts...
Page 75: ...ES 75...