33
EN
8
Open partially
(pedestrian
opening)
8-1
10%
This function can adjust the time of
opening partially.
The factory setting is « 8-2 »
8-2
20%
8-3
30%
8-4
40%
8-5
50%
8-6
60%
9
Pre-Flashing
9-0
The flashing light
blinks when the
gate starts to move
The factory setting is « 9-0 »
9-1
The flashing light
blinks 3 seconds
before the gate
starts to move
A
Over current
reverse setting
A-0
Stop
The factory setting is « A-3 » .
The reverse function only operates 3
times and then stops.
If gate reverses, the auto close
function will be cancelled.
A-1
Reverse 1 second
A-2
Reverse 3 seconds
A-3
Reverse to the end
C
Full open remote
switch
(on the remote
control)
C-1
the top left button
The factory setting is « C-1 » .
C-2
the top right button
C-3
the bottom left
button
C-4
the bottom right
button
E
Pedestrian open
remote switch
(on the remote
control)
E-0
No function in
transmitter
The factory setting is « E-2 »
E-1
the top left button
E-2
the top right button
E-3
the bottom left
button
E-3
the bottom right
button
7
Over current
setting
7-0
4A
The function can adjust the running
force of motor to be compatible with
the gate weight.
The factory setting is « 7-1 »
7-1
6A (fault)
7-2
8A
7-3
10A
7-4
12A
7-5
14A
7-6
16A
7-7
18A
7-8
20A
7-9
22A
Summary of Contents for MCO0062
Page 9: ...9 FR a b d C5 Installation et raccordement Branchement de l alimentation 230 volts...
Page 10: ...10 FR Feu clignotant CARTE COFFRET GND Feu LIGHT fil rouge Branchement polaris fil noir...
Page 27: ...27 EN C5 Installing 230V connection switch power supply a b d...
Page 28: ...28 EN Blinker ELECTRONIC CARD GND Feu LIGHT red wire black wire Polarized wiring...
Page 44: ...44 IT C5 Impianto Collegamento dell alimentazione 230 volt a b d...
Page 62: ...62 ES C5 Instalaci n y conexi n Cableado de la alimentaci n 230 volts a b d...
Page 63: ...63 ES Luz intermitente TARJETA GND Feu LIGHT cable rojo Cableado con polaridad cable negro...
Page 73: ......
Page 74: ......
Page 75: ......