39
Setting up the eyesite 550
1.
An alarm event is detected on a remote site, and the alarm system is activated.
2.
An output from the alarm panel is connected top the Zone 1 “sensor in” lines
on the eyesite 550.
The settings to sense the alarm panel output are:
Zone Menu:
• Input Mode-
Alarm In
• Input Sense-
Active High
3.
The eyesite 550 dials the central station by calling the phone number stored in
location 1 of the phonebook.
The setting to enable the autodialer is:
Communications Menu
• Autodialer
Alarm
4.
The eyesite 550 stores pre and post-event information automatically in its pre/
post event buffer.
The settings to enable the pre/post event buffer are:
Alarm Setup Menu
• Zone 1 Capture-
ON
• Post Capture Mode-
ON
5.
The central station’s eyesite for Windows Pro package rings, and is
automatically answered. The central site recording of video and audio starts.
6.
The intruder moves to another room triggering a passive infra-red sensor in
that location. The sensor is connected to the “sensor in” lines on interface 2,
and powered by the “power out” lines on interface 2. The eyesite 550 is
programmed to switch to zone 2 when the sensor is triggered.
The settings to sense the sensor output are:
Zone Menu:
• Input Mode-
Alarm In
• Input Sense-
Normally Open (NO)
7.
The operator takes appropriate action and the event continues to be
automatically tracked and recorded.
8.
The operator uploads the contents of the pre/post event buffer for review by
pressing, the
Pre/Post Control
button and navigating the available images and
video clips. Transfering clips releases the pre/post event buffer for a future
event, then disconnects from the remote site by pressing the
Hangup
button.
Summary of Contents for eyesite550
Page 1: ...eyesite550 User Manual ...
Page 54: ...50 ...
Page 68: ...62 ...
Page 78: ...72 ...
Page 102: ...96 ...
Page 110: ...104 ...
Page 111: ...105 Supported Networks and Operation ...
Page 112: ...106 ...
Page 113: ...107 Supported Networks and Operation ...
Page 114: ...108 ...