Output Mode
Disabled
The output is disabled and presents a high
impedance to any connected device.
Alarm Out
The output follows the input signal, but may be
the same or opposite depending on the selected outpout
sense
.
Latched
A latched output becomes fixed in the selected
output sense following a momentary trigger. This is useful in
applications where a light or a buzzer is required from a
momentary input such as an IR sensor.
Power Out
The output is permanently ON providing 12VDC
at 150 mA.
Pulsed
The output is remotely controlled and is pulsed for
500 ms. This mode is used when triggering lock solenoids
through the relay output module.
Ringer
The unit outputs a ringer signal for visual or audible
alerting of an event or alarm.
Signal
The incoming trigger signal is regenerated and output
for relay onto another device.
Output Sense
Active Low
connects the high impedance output to signal
ground assuming the output mode is not disabled.
Active High
Connects the high impedance output to +12v
DC.