Using the Compressor HMI
27
SCOTT SAFETY
087-0067 REV A
.
Table 12
Alerts with Override Default Settings - Compressor
ITEM
MEASUREM
ENT RANGE
ALARM
TIME
DELAY
RANGE
TIME
DELAY
ALARM
WARNING
ALARM
SHUTDOWN
ALARM
STATES
HORN
ALARM
MANUAL
OVERRIDE
OVERRI
DE
MAX.
LIMIT
COOL
DOWN
CYCLE
DP
Monit
or
-10 to -104F
0 to 30Min 10Min
-64F
-55F
Yes
Up to 3
(1Hr)
-10F
2Min
CO
Monit
or
0 to 200ppm
0 to 60Sec 30Secs
4ppm
6ppm
Yes
Up to 3
(1Hr)
20ppm
2Min
Oil
Pressu
re
SW
0 to 60Sec 25Sec
Below
30psi
Below 30psi
Yes
No
No
No
Air
Temp
eratur
e
100 to 600F
0 to 60Sec 15Sec
470F
495F
Yes
Up to 3
(1Hr)
550F
Yes
Crank
case
High
Temp
eratur
e
100 to 600F
0 to 60Sec 15Sec
325F
338F
Yes
Up to 3
(1Hr)
345F
2min
Crank
case
Min.
Temp
eratur
e
10 to 100F
0 to 60Sec 15Sec
32F
20F
Yes
Up to 3
(1Hr)
20F
2Min
Inlet
Air
Filter
SW
0 to 60Sec 15Sec
SW Closes No
No
No
No
No
Conde
nsatio
n
Reser
voir
Level
Dual Set Float
SW
0 to 60Sec 5Sec
2/3 Full
Full
Yes
No
No
No
Stage
#1
38 to 42psig
0 to
120Sec
10Sec
% of
output
press
No
Yes
Up to 3
(1Hr)
10%
No
Stage
#2
190 to
220psig
0 to
120Sec
20Sec
% of
output
press
No
Yes
Up to 3
(1Hr)
10%
No
Stage
#3
590 to
620psig
0 to
120Sec
30Sec
% of
output
press
No
Yes
Up to 3
(1Hr)
10%
No
Stage
#4
1300 to
1550psig
0 to
120Sec
40Sec
% of
output
press
No
Yes
Up to 3
(1Hr)
10%
No
Summary of Contents for HushAir Connect 7500
Page 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Page 2: ......
Page 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Page 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Page 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Page 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Page 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Page 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Page 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Page 119: ......