For The Installer: Environmental Limitations
The ice machine must be installed indoors in a
controlled environment.
Minimum
Maximum
Air Temp
55
0
F.
100
0
F.
Water Temp
40
0
F.
90
0
F.
Water Pressure 20 PSI
60 PSI
Voltage
103.5
126.5
Operating the ice machine outside of the above
limitations, or outdoors, is potentially damaging to
the machine, and it is misuse of the machine. This
may void the warranty.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL, NSF, and CSA.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
Airflow on air cooled models is:
••
Intake through the right side grill.
••
Exhaust through the back.
Do not install where this air flow is obstructed.
23"
SLE300
Top View
7"
3"
6
1
⁄
2
"
12"
6" Space Required for
Air Flow (Air Cooled
Only) and Utility
Connections
Dashed Lines Show
Outline of Ice Drop
Area.
Bin Control Mounts to
Right of Ice Drop Area.
SLE300
January 1995