15
25. Select
Superheat setpoint
and push
26. With “Arrows up-down” move to
8K
and push
27. Select
Valve opening at start-up
and push
28. With “Arrows up-down” move to
50%
and
push
29. With “Arrows up-down” move to page 5 of 11,
select
PID integral time
and push
30. With “Arrows up-down” move to
100 s
and
push
31. With “Arrows up-down” move to
PID
derivative time
and push
32. With “Arrows up-down” move to
5.0 s
and
push
33. With “Arrows up-down” go to page 6 of 11,
select
LowSH protect. threshold
and push
34. With “Arrows up-down” select
3K
and
35. With “Arrows up-down” move to page 6 of 11
LowSH protect. integral time
and push
36. With “Arrows up-down” select
10.0 s
and
push
37. With “Arrows up-down” go to page 7 of 11,
select
LOP protection threshold
and push
38. With “Arrows up-down” move to
-38°C
and
push
39. With “Arrows up-down” move to
LOP
protection integral time
and push
40. With “Arrows up-down” move to
5s
and push
41.
To move to Driver B push and hold for 2
seconds ENTER
and HELP together