![Scotsman MF 59 SPLIT Service Manual Download Page 13](http://html1.mh-extra.com/html/scotsman/mf-59-split/mf-59-split_service-manual_1218980013.webp)
11
12. Select
with
“Arrows up-down”
CONFIGURATION
and move to the page 5
of 11
13. Select
RELAY CONFIGURATION
and push
14. Move to
disabled
and confirm by pushing
15.
Push “Esc” to leave the
CONFIGURATION/SETTING
16. Select with “Arrows up-down”
REGULATION
and move to page 1 of 9
17. Select
Superheat setpoint
and push
18. With “Arrows up-down” move to
8K
and push
19. Select
Valve opening at start-up
and push
20. With “Arrows up-down” move to
50%
and
push
21. With “Arrows up-down” move to page 4 of 9,
select
PID integral time
and push
22. With “Arrows up-down” move to
100 s
and
push
23.
With “Arrows up-down” move to
PID
derivative time
and push
24. With “Arrows up-down” move to
5.0 s
and
push