SERVICE DIAGNOSIS: Ice Level Control Circuit

Electrical Shock Hazard Can
Cause Personal Injury.

Disconnect Power Before
Servicing.

Bin Thermostat Posts at Line
Voltage.

CONDITION

DETERMINE CAUSE

PROBABLE CORRECTION

Ice Machine does not run, it has
power to it, the high pressure
control is closed, the on/off switch is
set to ON.

A. Listen for a ticking sound from
transducer. 

If no noise, go to C. If there is a
noise, check for a light on the board
(models built after 4/93). If there is a
light on, check relay contacts N.O.
and COM. The contacts should be
CLOSED. If closed, go to D.  If not,
replace the board. If light is off, or
prior model, go to B.

B. Open bin door and twist
transducer 1/4 turn and pull out. 

DO

NOT UNPLUG with power
connected

. Examine the

transducer, the inside must be
clean and dry.

If the inside of the transducer
(above screen) was wet, replace it.
Set bin level to FULL and aim at an
object about 1-3 feet away.
Machine should restart, if not go to
D.

C. 

Check power to bin level

control board. 

Should be 12 volts from
transformer, if not replace
transformer. If there is power go to
D.

D. 

Disconnect electrical power

and test ice machine circuit by
attaching a jumper wire between bin
thermostat posts on circuit board
part no. 12-1912-01 (the circuit
board with the timer on it).
Reconnect power.

If machine does not start 

go back

to machine circuit.

 If machine

starts, disconnect electrical power,
remove jumper wire and reconnect
electrical power. Then go to E. 

E. Transducer or ice level board
assembly defective.

Replace transducer. Set bin level to
FULL and aim at an object about
1-3 feet away. Machine should
restart. If this does not repair unit,
replace the board.

Machine runs, makes ice, switches
on and off, but ice level cannot be
controlled.

Ice level switch may be defective.
On boards with a light, check by
moving switch & watching light.

Replace ice level switch

Machine runs, but will not shut off.

Board relay stuck closed. Check
relay.  

If COM and N.O. are closed when
power is off, replace board. If open,
go to B above.

MCM1062W

September  1993

Page 19

Summary of Contents for MCM1062

Page 1: ...cifications 2 Environmental Limitations 3 For the Installer Machine Bin Assembly 4 For the Plumber 5 For the Electrician 6 Final Check List 7 Initial Start Up 8 Adjustments 10 Component Description 11...

Page 2: ...ntrol box The unit comes from the factory with the correct refrigerant charge The refrigerant charge information is for recharging should that be necessary All utility connections are made at the back...

Page 3: ...vements at any time Specifications and design are subject to change without notice Water Limitations An ice machine is a food manufacturing plant it takes a raw material water and turns it into a food...

Page 4: ...ric water and drain See instructions for the plumber and for the electrician 2 Position the ice storage bin in the selected location 3 Level the bin in both the front to rear and side to side directio...

Page 5: ...supply and the cuber ln some cases a plumber will be required Drain Connections Drain tubing and fittings are supplied with the ice bin All drains are gravity type and must have a minimum of 1 4 inch...

Page 6: ...ause erratic operation and may be responsible for serious damage to the icemaker Electrical connections are made at the rear of the icemaker inside the junction box The cuber is packaged with a flexib...

Page 7: ...ave all electrical and piping connections been made 7 Are the Master and Compressor switches on OFF 8 Has power been connected to the ice maker 9 Is the water supply line shut off valve installed 10 C...

Page 8: ...Freezing time will range between 17 and 25 minutes Longer time for temperatures above 70 degrees F and shorter time required when temperatures are below 70 degrees F Average complete cycle time is abo...

Page 9: ...ROL The amount of ice maintained in the bin is adjustable The normal setting is full The level of ice in the bin may be set lower to shut off the machine when the bin is only partially full The ice bi...

Page 10: ...y area look at the cam and switch to observe the event B To start the FREEZING CYCLE Slowly rotate the shaft of the timer and switch assembly clockwise until the actuator arm on the microswitch initia...

Page 11: ...cycle Timer Timer Switch Assembly The timer begins to turn when activated by the cube size control The outer surface or large diameter lobe of the timer cam determines the length of time for finish f...

Page 12: ...able so that the ice machine will maintain a certain height of ice It will not fill any closer to the ice machine than 8 and will not work if the distance to the bottom of the bin is greater than 8 fe...

Page 13: ...e evaporator plates Gravity flow returns the unfrozen excess portion of water to the reservoir for recirculation Reservoir The reservoir located below the evaporators stores the inlet water charge and...

Page 14: ...e Size Control Reverse acting temperature control contacts close between 240 F and 00 F High Pressure Safety Switch Contacts open at 350 P S I G OPERATING CHARACTERISTICS The values listed below are r...

Page 15: ...8 Drain the reservoir again repeat step 5 9 Switch the machine to wash and continue to add fresh water to flush residual cleaner from the system Switch the Wash Off Ice switch off 10 Sanitize the ice...

Page 16: ...of the evaporator cover and the inside of the storage bin taking care to wipe all surfaces that are normally in contact with ice 10 Replace the evaporator cover Replace the front panel 11 Move the ma...

Page 17: ...run rest of ice machine does 1 Open contactor coil 1 Replace contactor 2 Thermostatic Expansion valve clogged or does not open 2 Check replace TXV No ice no water over evaporators 1 Water pump does no...

Page 18: ...ze wrong 5 Adjust cube size 6 Hot gas valve restricted 6 Replace hot gas valve 7 Not enough water to help harvest 7 Check for restriction of water supply 8 Head pressure too low 8 Check water reg pres...

Page 19: ...and aim at an object about 1 3 feet away Machine should restart if not go to D C Check power to bin level control board Should be 12 volts from transformer if not replace transformer If there is powe...

Page 20: ...t electrical power BEFORE removing transducer 2 Open bin door and locate the transducer socket 3 Twist inner portion of transducer counter clockwise and push up gently 4 Pull transponder down until pl...

Page 21: ...4 Unsnap and disconnect water distributor tubes from the water manifold section To replace the water distributor tubes and manifold tubes reverse the removal procedure BE SURE the notches in the wate...

Page 22: ...cloths or other efficient heat sink material 6 Sweat the tubing connections to the valve 7 Connect the electrical wires to the terminals of the valve coil 8 Weigh in the nameplate charge 9 Replace all...

Reviews: