COMPONENT DESCRIPTION
Control Box:
Contains the electrical controls that
operate the machine.
Low Pressure Cut Out:
An automatic reset switch
set to shut the machine off should the low side
pressure go below 15 PSIG.
High Pressure Cut Out
: An automatic reset
switch sensing the high side refrigeration pressure.
It is set to shut the machine off at 450 PSIG.
Evaporator:
A vertical stainless steel tube,
refrigerated, and water filled. In it there is a
stainless steel auger.
Reservoir:
Float operated, it maintains the water
level in the evaporator at a constant level, it also
contains the water level sensor.
Water Level Sensor:
Senses if there is water in
the reservoir to make ice out of. Will shut the
machine off it there is none.
Ice Discharge Chute
: Directs the ice made by the
evaporator into the storage bin.
Ice Level Sensor:
An electronic “eye”, it senses
the presence of ice in the bottom of the ice
discharge chute. Operates to turn the ice machine
on and off automatically as the level of ice in the
bin changes.
Gear Motor:
An oil filled, speed reduction
gearbox, driving the auger.
Cleaning Drain Tube
: When uncapped and
lowered, drains the evaporator.
Compressor:
The refrigerant vapor pump.
Condenser:
Air or water cooled, where the heat
removed in ice making is discharged.
Expansion valve
: The refrigerant metering
device.
NME1254 & FME1504
January 2000
Page 9
Control Box
Reservoir
Water Level Sensor
(Inside Reservoir)
Compressor
High Pressure
Cut Out
Condenser
Ice Chute
Expansion
Valve
Cleaning Drain
Tube
Ice Level Sensor
Evaporator
Gearmotor