C1448, C1848, C2148 E Series
Remote Condenser Models - User Manual
February 2016
Page 12
Electrical
The machine is not supplied with a power cord, the
machine must be hard-wired.
The dataplate on the back of the cabinet details
the power requirements, including voltage, phase,
minimum circuit ampacity and maximum fuse size.
HACR type circuit breakers may be used in place of
fuses. Extension cords are not permitted. Use of a
licensed electrician is recommended.
The ice maker is designed to operate on its own
electrical circuit and must be individually fused.
Voltage variation must not exceed the limits listed
earlier.
The remote condenser is designed to be powered
from the ice machine. A separate knockout hole has
been provided in the ice maker electrical junction box.
Electrical connections are made inside the junction
box in the back panel of the ice machine.
1. Remove the junction box cover and route the
power cord through the access hole and properly
attach the power supply wires to the leads in the
junction box.
2. Attach the remote condenser fan motor wires to
the wires in the junction box tagged “fan motor
leads”.
3. Install field supplied strain reliefs per code. Attach
a ground wire to the ground connection in the
junction box.
4. Check voltage when complete.
5. Return the junction box cover to its original
position and secure with the original screws.
Follow all applicable local, state and national
codes.
To Remote
Condenser
Fan Motor
Junction
Box
Cover
Power Supply
Wires
Ground Wire
Connection
Install
Strain
Relief
Install