Optional Accessories
Perimeter Sensor (SN-5)
Mounting the SN-5
The Perimeter sensor uses high frequency microwave technology to detect mass density
movement around the motorcycle. The signal can transmit through the seat, fiberglass, leather
and plastic, but not metal. It is recommended to place this sensor under the seat as close as
possible to the center of the motorcycle. With the provided Velcro, you can mount this sensor on
top of the battery or any flat surface, making sure that the top side of the sensor is facing
upwards. Place Perimeter sensor as far away as possible from the MCM.
Adjusting the Sensor
Although the sensor is pre set from the factory it may be necessary to adjust the sensitivity to suit
your specific application.
1.
Stand at least 10’ away from the motorcycle and arm the system.
2.
Walk towards the motorcycle and try and lean over the top of it. Once the sensor detects
movement the siren will begin to chirp slowly. If you back away from the motorcycle the siren
will stop chirping. If you continue to move closer to the motorcycle the siren will start to chirp
faster and faster and then go into a full alarm.
3.
Sensitivity can be adjusted by removing the plastic cap and tuning the adjustment screw. To
increase sensitivity, turn adjustment screw clockwise. To decrease sensitivity, turn the
adjustment screw counter clockwise.
4.
The Perimeter sensor has an internal tuning control, which has been set at the factory. This
tuning control should only be changed if the sensor can not be properly set as described in
#3 above, please call Aritronix’ technical support.
Plastic Cap:
Remove to adjust
sensitivity
To Accessory Harness on
Main Control Module (MCM)
Note: Do not turn sensitivity above half way. Doing so may cause false alarms.
12