Battery-Powered Single 

Station Smoke Alarm

Owner’

s Manual

110-1011E

Thank you for purchasing a Firex

®

smoke alarm. It is an important 

component of your home security system. Please read this booklet 

thoroughly. The more familiar you are with the information it 

contains, the easier you will find it to install, operate, and 

maintain your smoke alarm properly, which ultimately means 

greater security and peace of mind for you and your family.

Invensys Controls Americas

1 Smoke Alarm Features

2 Proper Placement of Your Smoke Alarm

3 Additional Smoke Alarm Placement Information

3 How to Install Your Smoke Alarm

3 Testing Your Smoke Alarm

4 LED Power/Alarm Indicator

4 Special Features of Model CC, CEC, CCPB and CPBC

4 Maintenance and Cleaning

5 Troubleshooting

5 Important Safety Information

5 Limited Warranty

6 Home Fire Safety Tips and Procedures

Table Of Contents

CB, CC,
CEC–Ionization-type,
CCPB Dual Sensor
Photoelectric /
Ionization-type,
CPBC–Photoelectric-type
sensor

Smoke Alarm Features

• Models CB, CC and CEC are ionization-type smoke alarms.

• Model CCPB is a dual sensor photoelectric / ionization-type smoke alarm.

• Model CPBC is a photoelectric-type smoke alarm.

• Unique “battery missing” feature. The smoke alarm will not attach to the mounting bracket if a battery

is not in the battery pocket.

• Low battery signal. The smoke alarm will sound a short beep about once a minute if the battery

needs replacement.

• Optional tamper-resist feature can serve as a safeguard against tampering.

• Visual LED flashes about once a minute. This indicates the smoke alarm is receiving power.

• Loud alarm horn—85 decibels at 10 feet—sounds to alert you of an emergency.

• Test button checks smoke alarm operation. Model CC, CEC, CCPB and CPBC features Alarm Control

(Quick-Quiet

). When activated, this quiets unwanted alarms for a maximum of 15 minutes.

• Model CEC features the Safety Light. This is a small light which will turn on when the smoke alarm

sounds its alarm horn, illuminating emergency exits.

The ionization type alarms are generally more effective at detecting fast, flaming fires which
consume combustible materials rapidly and spread quickly.  Sources of these fires may
include flammable liquids or paper burning in a waste container.  The photoelectric type
alarms are generally more effective at detecting slow, smoldering fires which smolder for
hours before bursting into flame.  Sources of these fires may include cigarettes burning in
couches or bedding.   However, both types of alarms are designed to provide adequate
detection of both types of fires.  If you desire the benefits of both systems, you should
install smoke alarms that combine in one alarm both photoelectric and ionization sensing
technologies.

S

T

A

TE

OF

CALIF

O

R

N

IA

S

T

A

T

E

FIRE MAR

S

H

A

L

L

I S

T I N

G

S

E

R V I C

E

110-1011E English  12/12/06  10:10 AM  Page 1

Summary of Contents for 110-1011E

Page 1: ...y pocket Low battery signal The smoke alarm will sound a short beep about once a minute if the battery needs replacement Optional tamper resist feature can serve as a safeguard against tampering Visual LED flashes about once a minute This indicates the smoke alarm is receiving power Loud alarm horn 85 decibels at 10 feet sounds to alert you of an emergency Test button checks smoke alarm operation ...

Page 2: ...ugh this is not required by the typical code or standard In addition we recommend that you interconnect all smoke alarms capable of being interconnected The smoke alarms referenced in this manual CANNOT be interconnected Interconnectable Firex smoke alarms include models G GC AD ADC FADC PAD and PG Invensys Controls Americas recommends a minimum of two smoke alarms in every home no matter how smal...

Page 3: ...ng bracket For Model CEC and CCPB the locking pin is molded into the plastic base 2 Place mounting bracket against ceiling or wall where you wish to mount the smoke alarm Use a pen cil to trace the inside of the two mounting hole locations 3 Drill two holes using a 3 16 in 5 mm drill bit in the centers of the hole locations and insert anchors into holes 4 Use mounting screws to secure mounting bra...

Page 4: ...larm Chamber Test Feature Models CCPB and CPBC only Once a minute Models CCPB and CPBC perform a chamber test If at any time the unit chirps and the LED does not flash see MAINTENANCE AND CLEANING section of this manual Battery Replacement Replace battery at least once a year or immediately when the low battery signal a chirp sounds once a minute Use only the following batteries as replacements in...

Page 5: ...old member may not hear the alarm e g outdoor or indoor noise sound sleepers drug or alcohol usage the hard of hearing etc If you suspect that this smoke alarm may not alert a household member install and maintain specialty smoke alarms Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household that are capable ...

Page 6: ...rials Watch them carefully Do not overload electrical circuits Limited Warranty Invensys Controls Americas warrants only to the original purchaser of this smoke alarm that other than the battery the smoke alarm is free from defects in material and workmanship under normal residential use and service for a period of five 5 years from the date of purchase Invensys Controls Americas warrants only to ...

Reviews: