Testing Your Smoke Alarm cont.

The center test button accurately tests all functions. NEVER use an open flame from a match or lighter
to test this smoke alarm. You may ignite and set fire to the smoke alarm and your home.

Test all smoke alarms weekly as follows:
1. Look at the LED power indicator. A visual light flashing about once a minute indicates the smoke

alarm is receiving battery power. See “LED Power/Alarm Indicator” chart.

2. Firmly depress the test button for at least five (5) seconds [ten (10) seconds for Model CCPB]. The

smoke alarm will sound its alarm horn loudly. The alarm may sound for up to 10 seconds after
releasing the test button.

3. If smoke alarm does not sound, replace the smoke alarm immediately. If the smoke alarm is under

warranty, see warranty information at the end of this manual for more information.

REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST FUNCTION DOES NOT OPERATE
PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED ABOVE (see REPAIR on page 5).

LED Power/Alarm Indicator

The visual LED indicates the following:

Special Features of Model CC, CEC, CCPB and CPBC

Alarm Control (Quick-Quiet

) (Models CC, CEC CCPB, and CPBC only)

When activated, Alarm Control (Quick-Quiet

) quiets unwanted alarms for a maximum of 15  minutes.

Always check that the smoke alarm has activated in a false alarm situation. Be sure a real fire emergency
does not exist.
To use the Alarm Control (Quick-Quiet

) feature:

Press and release the test button during an unwanted alarm. The alarm should stop within ten seconds.
The LED will flash about once every 10 seconds. This means the smoke alarm is in Alarm Control
(Quick-Quiet

) mode.

If the smoke alarm does not go into Alarm Control (Quick-Quiet

) and continues to sound its loud alarm

horn, or if it initially goes into Alarm Control (Quick-Quiet

) then resounds the alarm, the smoke is very

heavy. This is possibly a dangerous situation—-take emergency action immediately.

Safety Light (Model CEC only)

Model CEC features a Safety Light. This light turns on when the smoke alarm sounds. The Safety Light
is a miniature lamp which will last up to 15 hours of continuous operation. Its purpose is to assist in pro-
viding light in the escape route during a fire.

If the Safety Light does not turn on when the smoke alarm is tested, check the batteries. Replace the
batteries if necessary.

IMPORTANT: Smoke alarms with the Safety Light require two (2) AA batteries to operate the Safety
Light. These batteries are in addition to the 9-volt battery used to operate the smoke alarm.

Chamber Test Feature (Models CCPB and CPBC only)

Once a minute Models CCPB and CPBC perform a chamber test. If at any time the unit chirps and the
LED does not flash–see MAINTENANCE AND CLEANING section of this manual.

Battery Replacement

Replace battery at least once a year or immediately when the low battery signal (a chirp) sounds once a
minute. Use only the following batteries as replacements in this smoke alarm: Eveready 522 and 1222
(except Model CCPB), or Duracell MN 1604. Long Life Lithium replacement battery is Ultralife U9VL-J.

NOTE: For Model CEC, replace Safety Light batteries with two AA size batteries. Replace all  batteries
at the same time.

WARNING

DO NOT USE ANY OTHER TYPE OF BATTERY, EXCEPT AS SPECIFIED IN THIS 
MANUAL. DO NOT USE RECHARGEABLE BATTERIES.

1. Turn smoke alarm counter-clockwise to detach from mounting plate.

2. From back of smoke alarm, lift tab to open battery pocket door (Models CB, CC and CPBC only).

Remove battery from pocket. Disconnect and discard drained battery from battery connector.

3. Connect a fresh, 9-volt battery to connector. The battery will fit only one way. Be sure battery con-

nector is securely attached to battery terminals.

NOTE: For Model CEC, replace Safety Light batteries with two AA size batteries. Replace all batteries at the
same time.

4. Push test button for at least five (5) seconds [ten (10) seconds for Model CCPB]. The alarm horn

should sound. This means the battery is connected properly.

5. Place battery into battery pocket. Close battery pocket door. 

Push down until it snaps into place

.

6. Reattach smoke alarm to mounting plate. To do so, turn smoke alarm clockwise until it snaps into

mounting plate.

7. Test smoke alarm using test button as described on page 3, TESTING YOUR SMOKE ALARM.

Maintenance and Cleaning

In addition to weekly testing, this smoke alarm requires yearly battery replacement, and periodic cleaning
to remove dust, dirt, and debris. Long Life Lithium battery can be expected to last as long as five (5)
years, but is warrantied for one (1).

Cleaning

Clean the smoke alarm at least once a month to remove dust, dirt, or debris as follows:

• Using the wand attachment of a vacuum cleaner, vacuum all sides and cover of smoke alarm. Be sure

all the vents are free of debris.

• If necessary, remove battery and use a damp cloth to clean smoke alarm cover.

IMPORTANT: Do not attempt to remove the cover or clean inside the smoke alarm. THIS WILL VOID
YOUR WARRANTY.

!

Blinks once a minute

Normal operation–smoke alarm is receiving battery power

Blinks once a second

Smoke is detected; audible alarm will simultaneously sound

Models CC, CEC, CPBC and CCPB only:

Blinks once every 10 seconds 

Alarm Control (Quick-Quiet

) is actively quieting an unwant-

ed alarm

110-1011E English  12/12/06  10:10 AM  Page 4

Summary of Contents for 110-1011E

Page 1: ...y pocket Low battery signal The smoke alarm will sound a short beep about once a minute if the battery needs replacement Optional tamper resist feature can serve as a safeguard against tampering Visual LED flashes about once a minute This indicates the smoke alarm is receiving power Loud alarm horn 85 decibels at 10 feet sounds to alert you of an emergency Test button checks smoke alarm operation ...

Page 2: ...ugh this is not required by the typical code or standard In addition we recommend that you interconnect all smoke alarms capable of being interconnected The smoke alarms referenced in this manual CANNOT be interconnected Interconnectable Firex smoke alarms include models G GC AD ADC FADC PAD and PG Invensys Controls Americas recommends a minimum of two smoke alarms in every home no matter how smal...

Page 3: ...ng bracket For Model CEC and CCPB the locking pin is molded into the plastic base 2 Place mounting bracket against ceiling or wall where you wish to mount the smoke alarm Use a pen cil to trace the inside of the two mounting hole locations 3 Drill two holes using a 3 16 in 5 mm drill bit in the centers of the hole locations and insert anchors into holes 4 Use mounting screws to secure mounting bra...

Page 4: ...larm Chamber Test Feature Models CCPB and CPBC only Once a minute Models CCPB and CPBC perform a chamber test If at any time the unit chirps and the LED does not flash see MAINTENANCE AND CLEANING section of this manual Battery Replacement Replace battery at least once a year or immediately when the low battery signal a chirp sounds once a minute Use only the following batteries as replacements in...

Page 5: ...old member may not hear the alarm e g outdoor or indoor noise sound sleepers drug or alcohol usage the hard of hearing etc If you suspect that this smoke alarm may not alert a household member install and maintain specialty smoke alarms Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household that are capable ...

Page 6: ...rials Watch them carefully Do not overload electrical circuits Limited Warranty Invensys Controls Americas warrants only to the original purchaser of this smoke alarm that other than the battery the smoke alarm is free from defects in material and workmanship under normal residential use and service for a period of five 5 years from the date of purchase Invensys Controls Americas warrants only to ...

Reviews: