background image

9 Volt Battery Operated Smoke Alarm with “HUSH” Control to
temporarily silence nuisance alarms.

Thank you for purchasing this smoke and fire alarm.  It is an
important part of your family’s home safety plan.  You can trust
this product to provide the highest quality safety protection.  We
know you expect nothing less when the lives of your family are
at stake.

For your convenience, write down the following information.

If you call our Consumer Hotline, these are the first questions

you will be asked.

Smoke Alarm Model Number (located on back of alarm):

Date Code (located on back of alarm).  National Fire Protection Association
(NFPA) and the manufacturer recommends replacing this alarm ten years
from the date code:

Date of Purchase:

Where Purchased:

LISTED

DC3

Smoke and Fire Alarm

User’s Guide

For models: 0916, 440375

Summary of Contents for 916

Page 1: ...hing less when the lives of your family are at stake For your convenience write down the following information If you call our Consumer Hotline these are the first questions you will be asked Smoke Alarm Model Number located on back of alarm Date Code located on back of alarm National Fire Protection Association NFPA and the manufacturer recommends replacing this alarm ten years from the date code...

Page 2: ...tionalProtection IonizationTypeSmokeAlarmswith Hush ControlorPhotoelectricType DIAGRAM B 3 ft 0 9m 3 ft 0 9m HORIZONTAL DISTANCE FROM PEAK ANYWHERE IN THIS AREA DIAGRAM C This product is designed to detect products of combustion using the ionization tech nique It contains 0 9 microcurie of Americium 241 a radioactive material Distributed under U S NRC License No 32 23858 01E Manufactured in compli...

Page 3: ... is installed and test ing is complete When products of combustion are sensed the unit sounds a loud 85db pulsating alarm until the air is cleared HUSH CONTROL The HUSH feature has the capability of temporarily desensitizing the alarm circuit for approximately 7 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm is de...

Page 4: ... feature can be used repeatedly until the air has been cleared of the condition causing the alarm Pushing the test reset button on the alarm will end the hush period NOTE DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEATURE AND SOUND A CONTINUOUS ALARM CAUTION BEFORE USING THE ALARM HUSH FEATURE IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS FLASHING LED LIGHT This smoke ala...

Page 5: ...oke alarms in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms base ments and attached garages A C powered alarms will not operate if the A C power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition Smoke ...

Page 6: ...al power THE LIABILITY OF KIDDE SAFETY OR ANY OF ITS PARENT OR SUB SIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILURE OF TH...

Reviews: