Adjust the selectable relief pressure: press for 3 seconds the 

MAX 

 button, the display starts flashing. With 

SET

+ and 

SET-

 

you can adjust the value. After 2 seconds the display stops flashing and the set pressure is stored. There is the possibility 

to adjust the relief pressure from 30 to 70 mbar with respect to the working pressure. Example: if the desired pressure is 

set to 250 mbar and the value of discharging is set to 50 mbar, when the pressure of the inflatable structure rises to above 

300 mbar, the ARS

’s discharging valve opens and the ARS’s internal pressure returns to 250 mbar 

 

E. 

After  adjustment  press 

AUTO  CYCLE

:  2  LEDs  light  up  and  after  2  seconds,  the  ARS  will  inflate-refill  and  discharge 

automatically. With the automatic cycle switched on (LEDs ON) the UNIT automatically checks the pressure of the inflatable 
structure.  

 
 

 

TROUBLESHOOTING 

 

Problem 

Possible cause 

Possible Solution 

GE 2000 ARS 

 

doesn’t start 

Power cord not connected 

Connect the cable correctly. 

Main GREEN switch OFF  

Put the switch to ON.  

The power cord is damaged. 

Replace or repair the cable from a SCOPREGA Service 
Center. 

Inflator Stop 

Power cord not connected 

Connect the cable correctly. 

Main power switch OFF 

Put the switch to ON. 

Over-temperature 

Wait till the ARS has cooled down. Operation will resume 
automatically 

 
 
 
 

ACCESSORIES 
 

Recommended accessories for your ARS are available from your dealer. 

 

 

WARNING: USE OF ACCESSORIES NOT RECOMMENDED FOR THIS PRODUCT CAN BE DANGEROUS. 
MADE IN ITALY by 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for GE 2000 A.R.S.

Page 1: ...GE 2000 A R S 1 GE 2000 A R S INSTRUCTION MANUAL WARNING READ THIS MANUAL BEFORE OPERATING THE PRODUCT SAVE THIS INSTRUCTION MANUAL FOR REFERENCE ...

Page 2: ... determine that it will operate properly and perform its intended function 11 DO NOT OPERATE portable device near flammable liquids or in gaseous or explosive atmospheres 12 WARNING RISK OF UNSAFE OPERATION Do not modify or attempt to repair Never drill into or make any modifications to the device or its attachments INTENDED USE GE 2000 ARS is a system able to keep the nominal pressure inside a la...

Page 3: ...rn OFF the Green LED is signaling that the GE 2000 ARS will start to inflate at the preset pressure CHANGING THE PRESET PRESSURE TO CHANGE THE PRESET INFLATING CONTROLLING PRESSURE CAREFULLY FOLLOWS THIS INSTRUCTIONS 1 CONNECT THE POWER SUPPLY CABLE TO THE SPECIFIC SOCKET 2 TURN ON 1 THE MAIN GREEN SWITCH 3 TO ADJUST THE PRESSURE ACT AS FOLLOWS A PRESS MODE to select the measurement s units mbar p...

Page 4: ...LEDs light up and after 2 seconds the ARS will inflate refill and discharge automatically With the automatic cycle switched on LEDs ON the UNIT automatically checks the pressure of the inflatable structure TROUBLESHOOTING Problem Possible cause Possible Solution GE 2000 ARS doesn t start Power cord not connected Connect the cable correctly Main GREEN switch OFF Put the switch to ON The power cord ...

Page 5: ...GE 2000 A R S 5 GE 2000 A R S MANUALE D ISTRUZIONI ATTENZIONE LEGGERE QUESTO MANUALE PRIMA DI UTILIZZARE IL GONFIATORE CONSERVARE QUESTO MANUALE D ISTRUZIONI ...

Page 6: ...gre e che il gonfiatore operi nel modo nel quale per il quale è progettato 11 NON USARE IL GONFIATORE nei pressi di liquidi infiammabili o atmosfere esplosive 12 ATTENZIONE RISCHIO DI MALFUNZIONAMENTO Non modificare o tentare di riparare Non forare e non apportare Modifiche al dispositivo e ai suoi accessori MODALITA DI UTILIZZO GE 2000 ARS è un dispositivo in grado di mantenere la pressione nomin...

Page 7: ...E 2000 ARS inizierà a gonfiarsi alla pressione automaticamente CAMBIARE LE IMPOSTAZIONI DELLA PRESSIONE PER CAMBIARE LE IMPOSTAZIONI DI GONFIAGGIO E DI CONTROLLO DELLA PRESSIONE SEGUIRE LE SEGUENTI ISTRUZIONI 1 COLLEGARE IL CAVO DI ALIMENTAZIONE ALLA PRESA 2 ACCENDERE L INTERRUTTORE GENERALE VERDE 3 PER REGOLARE LA PRESSIONE SEGUIRE I SEGUENTI PASSI A PREMERE MODE per selezionare l unità di misura...

Page 8: ... ricaricare automaticamente Con il ciclo automatico attivato LED accesi l unità verifica automaticamente la pressione della struttura gonfiabile TROUBLESHOOTING Problem Possible cause Possible Solution GE 2000 ARS non parte Cavo alimentazione non collegato alla presa Collegarlo correttamente Interrutore principale VERDE spento Premere l interrutore Cavo di alimentazione danneggiato far sostituire ...

Reviews: