                               GE 2000 A.R.S. 

MAIN CHARACTERITICS 

 

1. 

Supply Voltage: 

 

 

 

210-240 Vac 50 Cycles or 110-130 Vac 60 Cycles 

 

2. 

Max. Power 

 

 

 

2000 W

 

3. 

Max preset pressure (Inflate and hold)  

350 mbar (5.1 psi)

 

4. 

Min preset pressure (Inflate and hold)   

50 mbar (0.7 psi) 

5. 

Selectable refill pressure 

 

 

from 30 to 70 mbar  

6. 

Selectable relief pressure 

 

 

from 30 to 70 mbar 

7. 

Max Flow rate (zero pressure) 

 

2000 l/min 

8. 

Dimensions 

 

 

 

400x170x h 260 mm 

9. 

Weight   

 

 

 

5 kg 

 

 

USE OF GE 2000 ARS 
 

1. 

Connect the Inflating tube to the Outlet Port of the GE 2000 ARS and 
to the Main  Valve of the inflatable structure 

2. 

Connect  the  fitting  (circled  in  the  picture  below)  to  a  different 
inflatable structure’s valve. Use a PU (or PA) tube with a diameter of 
6 mm and a length of 5 m MAX. 
 

 

ATTENTION:  CHECK THAT THE  PRESSURE-SENSOR  HOSE IS 
ALWAYS  CONNECTED  BETWEEN  THE  INFLATOR  AND  THE 
INFLATABLE STRUCTURE  

 

Pressure-sensor hose and 6 mm valve adapter is not included! 
 

 

3. 

Connect the Power Supply Plug to the specific Socket 

4. 

Turn ON (1) the Green Switch on the Inflator. The light on the switch will turn ON  

5. 

Press the AUTO CYCLE button. 2 LEDs light up and after 2 seconds the Red LED will turn OFF; the Green LED is signaling 
that  the  GE  2000  ARS  will  start  to  inflate  at  the  preset 
pressure. 

 
 

  

CHANGING THE PRESET PRESSURE 

 
TO CHANGE THE PRESET INFLATING/CONTROLLING PRESSURE 
CAREFULLY FOLLOWS THIS INSTRUCTIONS: 
 
 

 

1. 

CONNECT  THE  POWER  SUPPLY  CABLE  TO  THE 
SPECIFIC SOCKET 

 

2. 

TURN ON (1) THE MAIN GREEN SWITCH 

 

3. 

TO ADJUST THE PRESSURE ACT AS FOLLOWS: 

 

A. 

PRESS 

MODE 

to 

select 

the 

measurement’s units (mbar, psi, kPa, bar): 

press  many  times  the 

MODE

  button  until 

desired unit.  

B. 

Adjust  to  the  desired  working  pressure 

using  the 

SET+/SET-

  button:  press  a 

button  for  2  seconds,  the  display  starts 

flashing and you can change the pressure 

switch 

SET+

/

SET-

.  After  2  seconds  the 

display stops flashing and the set pressure 

is stored. The pressure is adjustable from 100 to 350 mbar  

C. 

Adjust the selectable refill pressure: press for 3 seconds the 

MIN

 button, the display starts flashing. With 

SET

+ and 

SET-

 

you can adjust the value. After 2 seconds the display stops flashing and the set pressure is stored. There is the possibility 

to adjust the refilling pressure from 30 to 70 mbar with respect to the working pressure. Example: if the desired pressure 

is set to 250 mbar and the value of refilling is set to 50 mbar, when the pressure of the inflatable structure falls below 200 

mbar, the GE 2000 ARS turns on and brings the pressure to 250 mbar  

Summary of Contents for GE 2000 A.R.S.

Page 1: ...GE 2000 A R S 1 GE 2000 A R S INSTRUCTION MANUAL WARNING READ THIS MANUAL BEFORE OPERATING THE PRODUCT SAVE THIS INSTRUCTION MANUAL FOR REFERENCE ...

Page 2: ... determine that it will operate properly and perform its intended function 11 DO NOT OPERATE portable device near flammable liquids or in gaseous or explosive atmospheres 12 WARNING RISK OF UNSAFE OPERATION Do not modify or attempt to repair Never drill into or make any modifications to the device or its attachments INTENDED USE GE 2000 ARS is a system able to keep the nominal pressure inside a la...

Page 3: ...rn OFF the Green LED is signaling that the GE 2000 ARS will start to inflate at the preset pressure CHANGING THE PRESET PRESSURE TO CHANGE THE PRESET INFLATING CONTROLLING PRESSURE CAREFULLY FOLLOWS THIS INSTRUCTIONS 1 CONNECT THE POWER SUPPLY CABLE TO THE SPECIFIC SOCKET 2 TURN ON 1 THE MAIN GREEN SWITCH 3 TO ADJUST THE PRESSURE ACT AS FOLLOWS A PRESS MODE to select the measurement s units mbar p...

Page 4: ...LEDs light up and after 2 seconds the ARS will inflate refill and discharge automatically With the automatic cycle switched on LEDs ON the UNIT automatically checks the pressure of the inflatable structure TROUBLESHOOTING Problem Possible cause Possible Solution GE 2000 ARS doesn t start Power cord not connected Connect the cable correctly Main GREEN switch OFF Put the switch to ON The power cord ...

Page 5: ...GE 2000 A R S 5 GE 2000 A R S MANUALE D ISTRUZIONI ATTENZIONE LEGGERE QUESTO MANUALE PRIMA DI UTILIZZARE IL GONFIATORE CONSERVARE QUESTO MANUALE D ISTRUZIONI ...

Page 6: ...gre e che il gonfiatore operi nel modo nel quale per il quale è progettato 11 NON USARE IL GONFIATORE nei pressi di liquidi infiammabili o atmosfere esplosive 12 ATTENZIONE RISCHIO DI MALFUNZIONAMENTO Non modificare o tentare di riparare Non forare e non apportare Modifiche al dispositivo e ai suoi accessori MODALITA DI UTILIZZO GE 2000 ARS è un dispositivo in grado di mantenere la pressione nomin...

Page 7: ...E 2000 ARS inizierà a gonfiarsi alla pressione automaticamente CAMBIARE LE IMPOSTAZIONI DELLA PRESSIONE PER CAMBIARE LE IMPOSTAZIONI DI GONFIAGGIO E DI CONTROLLO DELLA PRESSIONE SEGUIRE LE SEGUENTI ISTRUZIONI 1 COLLEGARE IL CAVO DI ALIMENTAZIONE ALLA PRESA 2 ACCENDERE L INTERRUTTORE GENERALE VERDE 3 PER REGOLARE LA PRESSIONE SEGUIRE I SEGUENTI PASSI A PREMERE MODE per selezionare l unità di misura...

Page 8: ... ricaricare automaticamente Con il ciclo automatico attivato LED accesi l unità verifica automaticamente la pressione della struttura gonfiabile TROUBLESHOOTING Problem Possible cause Possible Solution GE 2000 ARS non parte Cavo alimentazione non collegato alla presa Collegarlo correttamente Interrutore principale VERDE spento Premere l interrutore Cavo di alimentazione danneggiato far sostituire ...

Reviews: