GE 2000 A.R.S.
3
MAIN CHARACTERITICS
1.
Supply Voltage:
210-240 Vac 50 Cycles or 110-130 Vac 60 Cycles
2.
Max. Power
2000 W
3.
Max preset pressure (Inflate and hold)
350 mbar (5.1 psi)
4.
Min preset pressure (Inflate and hold)
50 mbar (0.7 psi)
5.
Selectable refill pressure
from 30 to 70 mbar
6.
Selectable relief pressure
from 30 to 70 mbar
7.
Max Flow rate (zero pressure)
2000 l/min
8.
Dimensions
400x170x h 260 mm
9.
Weight
5 kg
USE OF GE 2000 ARS
1.
Connect the Inflating tube to the Outlet Port of the GE 2000 ARS and
to the Main Valve of the inflatable structure
2.
Connect the fitting (circled in the picture below) to a different
inflatable structure’s valve. Use a PU (or PA) tube with a diameter of
6 mm and a length of 5 m MAX.
ATTENTION: CHECK THAT THE PRESSURE-SENSOR HOSE IS
ALWAYS CONNECTED BETWEEN THE INFLATOR AND THE
INFLATABLE STRUCTURE
Pressure-sensor hose and 6 mm valve adapter is not included!
3.
Connect the Power Supply Plug to the specific Socket
4.
Turn ON (1) the Green Switch on the Inflator. The light on the switch will turn ON
5.
Press the AUTO CYCLE button. 2 LEDs light up and after 2 seconds the Red LED will turn OFF; the Green LED is signaling
that the GE 2000 ARS will start to inflate at the preset
pressure.
CHANGING THE PRESET PRESSURE
TO CHANGE THE PRESET INFLATING/CONTROLLING PRESSURE
CAREFULLY FOLLOWS THIS INSTRUCTIONS:
1.
CONNECT THE POWER SUPPLY CABLE TO THE
SPECIFIC SOCKET
2.
TURN ON (1) THE MAIN GREEN SWITCH
3.
TO ADJUST THE PRESSURE ACT AS FOLLOWS:
A.
PRESS
MODE
to
select
the
measurement’s units (mbar, psi, kPa, bar):
press many times the
MODE
button until
desired unit.
B.
Adjust to the desired working pressure
using the
SET+/SET-
button: press a
button for 2 seconds, the display starts
flashing and you can change the pressure
switch
SET+
/
SET-
. After 2 seconds the
display stops flashing and the set pressure
is stored. The pressure is adjustable from 100 to 350 mbar
C.
Adjust the selectable refill pressure: press for 3 seconds the
MIN
button, the display starts flashing. With
SET
+ and
SET-
you can adjust the value. After 2 seconds the display stops flashing and the set pressure is stored. There is the possibility
to adjust the refilling pressure from 30 to 70 mbar with respect to the working pressure. Example: if the desired pressure
is set to 250 mbar and the value of refilling is set to 50 mbar, when the pressure of the inflatable structure falls below 200
mbar, the GE 2000 ARS turns on and brings the pressure to 250 mbar