background image

                               GE 2000 A.R.S. 

 

 

 

  WARNING! Read all instructions before operating the inflator

. Failure to follow all instructions listed below may result in 

product damage, and/or serious injury. 

 

SAVE THESE INSTRUCTIONS

 

 

  WARNINGS: 

 

1. 

Read these instructions. 

2. 

Keep these instructions. 

3. 

Protect the cord and the Pressure-Sensor Hose from being walked on or pinched.  

4. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way. 

5. 

Do

n’t disassemble the product. Incorrect reassembly may result in a risk of Short Circuit. 

6. 

Keep this product out of the reach of children. 

 

DO NOT SUPPLY THE INFLATOR AT HIGHER OR LOWER VOLTAGE THAN NOMINAL.  

 

GENERAL SAFETY RULES 

 

7. 

CONSIDER WORK AREA ENVIRONMENT. 

Donʼt expose the device to heavy rain. Donʼt use in presence of flammable liquids 

or gases.  

8. 

DONʼT ABUSE CORD. 

Never carry device by cord or yank it to disconnect from receptacle. Keep cord from heat, oil, and sharp 

edges.  

9. 

STAY ALERT. 

Watch what you are doing. Use common sense.  

10. 

CHECK DAMAGED PARTS. 

Before further use of the device, a guard or other part that is damaged should be carefully checked 

to determine that it will operate properly and perform its intended function.  

11.  DO NOT OPERATE 

portable device near flammable liquids or in gaseous or explosive atmospheres. 

 

12. 

WARNING! RISK OF UNSAFE OPERATION. 

Do not modify or attempt to repair. Never drill into or make any modifications to 

the device or its attachments.  

 

INTENDED USE 

 
GE 2000 ARS is a system able to keep the nominal pressure inside a large inflatable structures within pre-set values (min. 50 mbar, max. 
400 mbar), independently from ambient temperature.  The unit constantly monitors the pressure variation inside the inflatable structure 
and regulates the operation to ensure pressure top-up and pressure relief.  

 

1. 

The GE 2000 ARS (is a unit able to INFLATE, MAINTAIN A PRESET PRESSURE and DEFLATE a LARGE INFLATABLE 
STRUCTURE. THAT MEANS THE UNIT MUST BE ALWAYS BE CONNECTED TO THE INFLATABLE. 

 

2. 

THE  ARS  IS  DELIVERED  WITH  A  FACTORY  PRESSURE  SET.  IF  THE  SET  PRESSURE  NEEDS  TO  BE  CHANGED, 
PLEASE FOLLOW CAREFULLY THE INSTRUCTIONS CONTAINED IN THIS MANUAL. IN CASE OF DOUBTS PLEASE 
CONTACT SCOPREGA.

 

3. 

THE  INFLATOR  IS  PROVIDED  WITH  HOSES  AND  ADAPTORS  TO  BE  CONNECTED  TO  THE  MOST  COMMON 
INFLATION VALVES

 

4. 

THE  INFLATOR  IS  FITTED  WITH  TERMAL  OVERLOAD  SWITCHES  THAT  WILL  INTERVENE  IN  CASE  OF 
OVERHEATING. NORMAL OPERATION WILL RESUME AUTOMATICALLY AFTER A PAUSE OF 20/40 MINUTES

  

 
 

 

Summary of Contents for GE 2000 A.R.S.

Page 1: ...GE 2000 A R S 1 GE 2000 A R S INSTRUCTION MANUAL WARNING READ THIS MANUAL BEFORE OPERATING THE PRODUCT SAVE THIS INSTRUCTION MANUAL FOR REFERENCE ...

Page 2: ... determine that it will operate properly and perform its intended function 11 DO NOT OPERATE portable device near flammable liquids or in gaseous or explosive atmospheres 12 WARNING RISK OF UNSAFE OPERATION Do not modify or attempt to repair Never drill into or make any modifications to the device or its attachments INTENDED USE GE 2000 ARS is a system able to keep the nominal pressure inside a la...

Page 3: ...rn OFF the Green LED is signaling that the GE 2000 ARS will start to inflate at the preset pressure CHANGING THE PRESET PRESSURE TO CHANGE THE PRESET INFLATING CONTROLLING PRESSURE CAREFULLY FOLLOWS THIS INSTRUCTIONS 1 CONNECT THE POWER SUPPLY CABLE TO THE SPECIFIC SOCKET 2 TURN ON 1 THE MAIN GREEN SWITCH 3 TO ADJUST THE PRESSURE ACT AS FOLLOWS A PRESS MODE to select the measurement s units mbar p...

Page 4: ...LEDs light up and after 2 seconds the ARS will inflate refill and discharge automatically With the automatic cycle switched on LEDs ON the UNIT automatically checks the pressure of the inflatable structure TROUBLESHOOTING Problem Possible cause Possible Solution GE 2000 ARS doesn t start Power cord not connected Connect the cable correctly Main GREEN switch OFF Put the switch to ON The power cord ...

Page 5: ...GE 2000 A R S 5 GE 2000 A R S MANUALE D ISTRUZIONI ATTENZIONE LEGGERE QUESTO MANUALE PRIMA DI UTILIZZARE IL GONFIATORE CONSERVARE QUESTO MANUALE D ISTRUZIONI ...

Page 6: ...gre e che il gonfiatore operi nel modo nel quale per il quale è progettato 11 NON USARE IL GONFIATORE nei pressi di liquidi infiammabili o atmosfere esplosive 12 ATTENZIONE RISCHIO DI MALFUNZIONAMENTO Non modificare o tentare di riparare Non forare e non apportare Modifiche al dispositivo e ai suoi accessori MODALITA DI UTILIZZO GE 2000 ARS è un dispositivo in grado di mantenere la pressione nomin...

Page 7: ...E 2000 ARS inizierà a gonfiarsi alla pressione automaticamente CAMBIARE LE IMPOSTAZIONI DELLA PRESSIONE PER CAMBIARE LE IMPOSTAZIONI DI GONFIAGGIO E DI CONTROLLO DELLA PRESSIONE SEGUIRE LE SEGUENTI ISTRUZIONI 1 COLLEGARE IL CAVO DI ALIMENTAZIONE ALLA PRESA 2 ACCENDERE L INTERRUTTORE GENERALE VERDE 3 PER REGOLARE LA PRESSIONE SEGUIRE I SEGUENTI PASSI A PREMERE MODE per selezionare l unità di misura...

Page 8: ... ricaricare automaticamente Con il ciclo automatico attivato LED accesi l unità verifica automaticamente la pressione della struttura gonfiabile TROUBLESHOOTING Problem Possible cause Possible Solution GE 2000 ARS non parte Cavo alimentazione non collegato alla presa Collegarlo correttamente Interrutore principale VERDE spento Premere l interrutore Cavo di alimentazione danneggiato far sostituire ...

Reviews: