26
Condition/Problem
Things to Check
Solution
No display/partial
display/unit will not
turn on
Check electrical (wall)
outlet
Make sure unit is plugged into a
functioning wall outlet.
Check connection at unit
Connection should be secure and
undamaged. Replace adapter or
connection at unit if either are dam-
aged.
Check data cable integrity
All wires in cable should be intact.
If any are visibly crimped or cut,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly.
Check console display for
damage
Check for visual sign that console
display is cracked or otherwise dam-
aged. Replace Console if damaged.
If the above steps do not resolve the
problem, contact Customer Care for
further assistance.
No speed/RPM
reading,
Check data cable integrity
All wires in cable should be intact.
If any are cut or crimped, replace
cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly.
Check magnet position
(requires shroud removal)
Magnets should be in place on pul-
ley.
Check Speed Sensor
(requires shroud removal)
Speed sensor should be aligned with
magnet and connected to data cable.
Realign sensor if necessary. Replace
if there is any damage to the sensor
or the connecting wire.
Resistance does
not change (ma-
chine turns on and
operates)
Check Resistance Shifter
Check for visual sign that Resistance
Shifter is damaged. Replace Resis-
tance Shifter if damaged.
If the above steps do not resolve the
problem, contact Customer Care for
further assistance.