Solar Energy Systems 01.09.2009
Page
35
Mounting Directions for In-Roof Photovoltaic Systems
Ernst Schweizer AG, Metallbau, CH-8908 Hedingen, T41 44 763 61 11, T41 44 763 61 19, www.schweizer-metallbau.ch
4. Connect the individual flashings with a join capping piece profile (cf. Image 3-13, p. 17).
Image 4-21: Placing the join capping piece profile
5. Cover the rest of the roof surface with tiles.
Image 4-22: Roof integration on a tiled roof (ridge)
1 Photovoltaic
module
4
Roof
tile
2 Mounting clamp “profile”
5
Tile batten
3 Flashing ridge
6
Mounting board
TIP
Warmth emitted from the photovoltaic modules lessens the system’s output. Sufficient ventilation of the modules
minimizes the output loss.
High module temperatures lessen the system’s output.
Ventilation in the counter-batten area reduces module temperature and diverts the warmth up and away.
Do not obstruct the free movement of air between the counter-battens.
Divert the ventilation cross section of the counter-battens across the module array and up and away.
Convert the roof ridge into a ventilating ridge with enough ventilation cross sections.