Solar Energy Systems 01.09.2009
Page
26
Mounting Directions for In-Roof Photovoltaic Systems
Ernst Schweizer AG, Metallbau, CH-8908 Hedingen, T41 44 763 61 11, T41 44 763 61 19, www.schweizer-metallbau.ch
Image 4-7: Module installation order
TIP
Make sure that the inverter cable and the circuit connecting cables have been installed before installing the
modules.
Lead the module circuit connecting cable to the left before laying the module for contact access to the
following module.
1. In the lowest row of the first column to the right inlay the first photovoltaic module in the mounting clamp.
Thereby mind that the drainage channels of the frame profile are on the left and the open lamination edge on
the bottom.
2. Inlay flashing profiles and if necessary flashings on the right with the frame profiles at the panel edge in the
clamp.
Image 4-8: Mounting the first module