7
STS
-
JZ
-
F / IQ
-
F I&O Manual Z83.20
-
2016
IM101220
RD: APR 2019
RL: 20C
TABLE 1 MINIMUM CLEARANCES TO COMBUSTIBLES*
FIGURE 1 MINIMUM CLEARANCES TO COMBUSTIBLES*
-
refer to
Table 1
for values
*The clearance to combustible materials represents the minimum distance that must be main-
tained between the heater and a nearby surface.
The stated clearance to combustibles
represents a surface temperature of 90F° (50C°) above room temperature.
.
NOTE: A
‘
PEEL & STICK
’
SIGN IS SUPPLIED:
USE AN INDELIBLE MARKER TO
ENTER VALUES
‘
H
’, ‘
S
’, ‘
F
’, & ‘
B
’
ON .
POST THE SIGN ADJACENT TO THE HEATER THERMOSTAT OR IN A
PROMINENT LOCATION.
See next page for details.
F
D
B
A
S
S
C
Suspended at an
angle up to 45°
Suspended
horizontally
C
FLOOR
H
T
H
Maximum Stack
Height
H
= T
-
C
‘
T
’
is measured
on site,
‘
C
’
is in
Table 1
FLOOR
T
Maximum Stack
Height
H
= T
-
C
‘
T
’
is measured
on site,
‘
C
’
is in
Table 1
MODEL
SUSPENDED AT AN ANGLE
UP TO 45 DEGREES
SUSPENDED
HORIZONTALLY
D
inches
(cm)
B
inches
(cm)
F
inches
(cm)
C
inches
(cm)
A
inches
(cm)
S
inches
(cm)
C
inches
(cm)
STS
-
JZ / IQ 200
13
(33)
6
(15.2)
74
(188)
70
(178)
14
(36)
44
(112)
76
(193)
STS
-
JZ / IQ 175
12
(31)
6
(15.2)
72
(183)
68
(172)
13
(33)
42
(107)
74
(188)
STS
-
JZ / IQ 155
5.5
(14)
1
(2.5)
64
(163)
64
(163)
3.5
(9)
22
(48)
70
(178)
STS
-
JZ / IQ 130
4.5
(11)
1
(2.5)
60
(152)
60
(152)
3.3
(9)
21
(28)
65
(165)
STS
-
JZ / IQ 110
3.5
(9)
1
(2.5)
54
(137)
54
(137)
2
(5)
19
(25)
60
(137)
STS
-
JZ / IQ 100
6.5
(16.5)
1
(2.5)
57
(145)
68
(172)
6
(15)
22
(56)
68
(172)
STS
-
JZ / IQ 80
3
(8)
1
(2.5)
23
(59)
38
(97)
1.75
(5)
6
(15)
38
(97)
STS
-
JZ / IQ 60
2.5
(6)
1
(2.5)
17
(43)
34
(86)
1.5
(4)
5.5
(14)
34
(86)
STS
-
JZ / IQ 45
2.75
(7)
1
(2.5)
24
(61)
32
(81)
2.25
(6)
7
(18)
32
(81)