Fieldbus Monitor
26
01.00|WSG |en
Bit No. Flag Name
Description
D4
SF_SOFT_LIMIT_MINUS
Negative direction soft limit reached
The flag is set if the fingers have reached the defined soft
limit in negative moving direction. A further movement
into this direction is not allowed any more.
This flag is cleared if the fingers are moved away from the
soft limit position.
D3
SF_BLOCKED_PLUS
Axis is blocked in positive moving direction
The flag is set if the axis is blocked in positive moving di-
rection.
The flag is reset if either the blocking condition is resolved
or a stop command is issued.
D2
SF_BLOCKED_MINUS
Axis is blocked in negative moving direction
The flag is set if the axis is blocked in negative moving
direction.
The flag will be reset if either the blocking condition is
resolved or a stop command is issued.
D1
SF_MOVING
The Fingers are currently moving
This flag is set whenever a movement is started, e.g.
MOVE command.
The flag will reset automatically as soon as the movement
stops.
D0
SF_REFERENCED
Fingers Referenced
The flag is set when the gripper was referenced by a
HOMING command.
Only after homing motion commands can be executed.
3
Overdrive mode is not supported by all grippers. Please refer to the assembly and oper-
ating manual of the gripper for further information.