Assembly
22
04.00|1400904 NSP 140, NSP-S 140 |en-US
Connection assignment
Pin
Color
Description
1
brown
Supply voltage 11.5 V ... 30 V
2
white
Ground GND
3
green
Output signal 2 V ... 10 V
4
Increase points away from the module
The maximum cable length is 3 m.
In order to minimize electrical interference, it is recommended the
shield winding be connected to the machine housing.
Clamping rings SRA, SRB, SRC
Clamping rings
The clamping rings SRA, SRB and SRC of the NSP are fastened in
the installation space with 12 screws M10 of strength class 12.9.
Two M12 forcing threads are provided on the clamping ring to
facilitate removal.
If the turbo connection is not used, it must be connected to ensure
that the oil is returned.
If several linked clamping units are mounted on a pallet, make sure
that the flatness and height deviation of the locating surfaces of all
of the locating holes lie within the permissible tolerance range of
±0.01 mm. Otherwise, the optimum clamping and repeat accuracy
of the quick-change pallet system cannot be guaranteed.
When aligning the clamping rings to the clamping module, it must
be ensured that the flat surface between the cylinder head
countersinks is resting on the locating points of the clamping
module.
When using the air control function
, it must be
ensured that the clamping rings are in the right position
orientation. The air outlet openings on the raised locating surfaces
of the clamping module must be completely covered by the flat
surface of the clamping ring. The cylinder head countersinks of the
clamping ring must therefore not be orientated towards the air
outlet holes.
Request our installation drawings of the clamping rings if doing the
installation yourself.
6.3