Assembly
20
04.00|1400904 NSP 140, NSP-S 140 |en-US
The NSP 140 is fastened in the installation space with 8 screws
M12 (item 20) of strength class 12.9. The clamping module is
sealed via an O-ring (item 45 in the accessory kit) in the bore hole
of the module mount.
The built-in clamping module is positioned via the centering
diameter of the installation space:
Ø 96H6.
With the NSP-S 140, a
pin (item 25) is additionally used. This secures rotation of the
module in relation to the plate or table. The pin also serves as
positional orientation for the electrical transfer on the NSP-S 140.
All base-side air connection openings for "Open module" and the
turbo function are sealed with set-screws (item 26) on delivery.
As standard, the hydraulic and air connections are established via
the coupling bore on the lower face side of the quick-change pallet
module. For axial sealing, the O-rings (item 30) must be inserted in
the base-side O-ring seats of the clamping module.
The accessory kit of the NSP 140 contains the O-rings (item 30) for
sealing the hose-free direct connections on the base side.
When the turbo connection is used, the spring-actuated locking
procedure is actively supported with hydraulic pressure. If the
turbo connection is not used, it must be connected to ensure that
the oil is returned.
Request our installation drawings if performing the installation
yourself.
The NSP 140 features dynamic pressure monitoring of the
clamping ring and contact monitoring via dynamic pressure
monitoring of the clamping slides. Via two separate air
connections, the clamping slide position can be monitored in
"OPENED" and/or "CLOSED" status alternately.
The monitoring functions can be monitored via an electronic
pressure switch. A pressure switch signals to the operator or the
machine which position the clamping slides are in or if the
clamping pallet is completely flush and locked.
The air connection for the monitoring functions is via the coupling
hose on the lower face side of the quick-change pallet module as
standard.
Remove the set-screw (item 26) to make this connection. For axial
sealing, the O-rings (item 30) must be inserted in the base-side O-
ring seats of the clamping module.
The accessory kit contains the O-rings (item 30) for sealing the air
connection. The O-rings must be fitted even when contact
monitoring is not used.