Maintenance and care
32
04.00 | KSP3, KSP3-LH, KSP3-F | TANDEM Clamping Block | en | 1463318
Remove screws (65) and pull out cover (5)
together with O-ring (45) and flat gaskets (48) out
of the housing. To do this, screw two screws into
the threaded holes as an extraction tool
for size 64: M3 x L>25
for size 100: M3 x L>25
for size 140: M4 x L>25
for size 160: M3 x L>25
for size 200: M5 x L > 25
for size 250: M5 x L>25
for size 315: M6 x L>25
Variant with clamping force maintenance (AS)
Fasten mounting cover (200) with cheese-head
screws DIN EN ISO 4762. Mounting
cover
for size 64: M3 x 12
for size 100: M5 x 8 -14
for size 140: M5 x 12 - 16
for size 160: M5 x 16 - 20
for size 200: M5 x 16 - 20
for size 250: M6 x 20 - 25
for size 315: M8 x 25