![SCHUNK TANDEM KSP3 Assembly And Operating Manual Download Page 12](http://html1.mh-extra.com/html/schunk/tandem-ksp3/tandem-ksp3_assembly-and-operating-manual_1215813012.webp)
Basic safety notes
12
04.00 | KSP3, KSP3-LH, KSP3-F | TANDEM Clamping Block | en | 1463318
2.13.3 Protection against dangerous movements
Unexpected movements
Residual energy in the system may cause serious injuries while
working with the product.
• Switch off the energy supply, ensure that no residual energy
remains and secure against inadvertent reactivation.
• Never rely merely on the response of the monitoring function
(dynamic pressure monitoring with pressure sensors) to avert
danger. Assume that the drive movement is faulty as long is the
installed monitors are not effective, since the effect depends on
the control and the current operating state of the drive.
Perform maintenance, modification and attachment work
outside of the danger zone defined by the movement range.
• To avoid accidents and/or material damage, human access to
the movement range of the machine must be restricted. Limit/
prevent accidental access for people in this area due through
technical safety measures. The protective cover and protective
fence must be rigid enough to withstand the maximum possible
movement energy. EMERGENCY STOP switches must be easily
and quickly accessible. Before starting up the machine or
automated system, check that the EMERGENCY STOP system is
working. Prevent operation of the machine if this protective
equipment does not function correctly.
2.13.4 Notes on particular risks
WARNING
Risk of injury in the event of workpiece loss due to component
failure on the product as a result of exceeding the technical data.
•
The product may only be used within the scope of its technical
data
WARNING
Risk of injury due to immediate closing of the product with high
spring force in the event of pneumatic pressure failure (AS variant).
•
Ensure stable compressed air supply
•
Use pressure maintenance valves
WARNING
Risk of injury in the event of workpiece loss due to failure or
pressure reduction of the compressed air.
•
Ensure stable compressed air supply
•