Operation
30
03.00|Clamping device SVP-Mini auto/SVP-RM auto|en
NOTE
Programmes have already been saved in the pump control ex works.
It is possible to save further programmes, see section
Select programme
NOTICE
Material damage caused by too high clamping pressure.
If the clamping pressure is too high, the clamping unit and the po-
lygonal jaw chuck may deform.
• Do not use programme "P01: Standard". This programme is only
intended for SCHUNK service personnel.
• Do only use programme "P02: Tribos-Mini_AD9" for SVP-Mini
auto.
• Do only use programme "P03: Tribos-RM-AD20" for SVP-RM au-
to.
1 Select programme (3) and press "enter".
Programme for SVP-Mini auto
Programme for SVP-RM auto
2 Select the required programme and press "enter".
Programme number, programme designation and the saved tar-
get pressure are displayed under the "main page" tab.
NOTE
When switching the pump on again, the last selected programme is
highlighted black.