Operation
03.00|Clamping device SVP-Mini auto/SVP-RM auto|en
27
Operation modes of "function" LED
Color
Meaning
Orange
Lights up when switching on
Green
Lights up if clamping cycle is functioning well.
Red
Lights up if clamping cycle is faulty.
Red and green Flashes if maintenance is due.
Operating the pump
Switching pump on and off
1 Press "enter" to turn the pump on.
The pump is ready for operation.
2 Press and hold "enter" for 3 seconds to turn the pump off.
NOTE
If the control programme is not operated, the pump turns into sleep
mode after 3 minutes. The display turns off and can be turned on
again by pressing "enter".
6.2
6.2.1