Operation
03.00|Clamping device SVP-Mini auto/SVP-RM auto|en
47
Charging the battery
1 Insert the battery (1) in the charger (5).
2 Plug the plug of the charger in an appropriately installed socket.
The battery is charged. The LED (6) of the charger lights up red.
The battery must be charged for 60 minutes.
If the battery is fully charged, the LED (6) of the charger lights
up green.
3 Remove the battery from the charger.
4 Unplug the plug from the socket.
Displaying the battery status.
NOTE
If the pump is de-energized, the battery status display of the battery
in the pump is inaccurate.
1 Remove the battery from the pump.
OR: Switch off the pump at least one minute before recalling the
battery status.
2 Push the button (3).
The number of LEDs (2) lighting up on the battery indicates the
battery status.
Number of LEDs
lighting up
Battery status
4
78 – 100%
3
55 – 77%
2
33 – 54%
1
10 – 32%
1 flashes
10% or less
The optimum charging level is between 50% and 80%.
Note: The battery status display is only for identifying the power re-
serve. The actual power consumption depends on the adjusted work
parameters.