Assembly
1. Move product to the "gripper open" position.
2. Loosen screw (4) and remove control cam (6) for the inductive
monitoring from the base jaw.
3. Remove screw (5) from the base jaw.
4. Apply adhesive to the top and sides of the control cam (6) from
the mounting kit.
✓
Make sure that there is no adhesive on the bottom of the
control cam (6), which comes into contact with the sensor.
✓
SCHUNK recommends the adhesive Loctite 290 or 638.
5. Slide control cam (6) into the base jaw to the stop.
✓
Ensure that the higher front side of the control cam (6) is
pointing outwards.
6.
IMPORTANT! The control cam (6) must no longer move after
it is screwed on.
Screw the control cam (6) to the base jaw using the screw (5).
✓
Secure the screw (5) with medium-strength locking liquid.
7. Slide the sensor (1) to the stop into the bracket (2).
8. Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
9. Adjust sensor (1), see assembly and operating manual of the
sensor.
Variant Dust-tight:
Screw in set-screw into the side cover.
39
10.00 | PZV | Assembly and Operating Manual | en | 389384