Assembly
5.3.11 Mounting the reed switch RMS 80
CAUTION
Blockade of the gripper after setting or replacing of the
switching cam!
The switching cam can be tilt in the guide, if it was not fixed
exactly in the base jaw.
•
Apply the switching cam in the direction of the base jaw, so
that the cam does not contact the housing of the gripper.
NOTE
The positions "Gripper open" and "Gripper closed" have been set
in the factory.
Variant Dust-tight:
Before attaching the sensor, remove the sealing bolts from the
bracket. Before adjusting the control cam, unscrew the set-screw
from the side cover.
Position "Gripper open" or "Part gripped (I.D. gripping)"
1. Slide the sensor 1 (1) into the bracket (2) until it stops.
2. Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
3. Open gripper or grip part.
4. Unfasten the screw (4).
5. Turn the screw (5) to adjust the position of the control cam (6).
✓
Slide control cam (6) inwards until the sensor 1 (1) no longer
responds.
Move the control cam (6) back towards the outside until the
sensor 1 (1) begins to switch.
35