Basic safety notes
2.13.4 Protection against electric shock
Possible electrostatic energy
Components or assembly groups may become electrostatically
charged. When the electrostatic charge is touched, the discharge
may trigger a shock reaction leading to injuries.
• The operator must ensure that all components and assembly
groups are included in the local potential equalisation in
accordance with the applicable regulations.
• While paying attention to the actual conditions of the working
environment, the potential equalisation must be implemented
by a specialist electrician according to the applicable
regulations.
• The effectiveness of the potential equalisation must be verified
by executing regular safety measurements.
2.14 Notes on particular risks
DANGER
Risk of fatal injury from suspended loads!
Falling loads can cause serious injuries and even death.
•
Stand clear of suspended loads and do not step within their
swiveling range.
•
Never move loads without supervision.
•
Do not leave suspended loads unattended.
•
Wear suitable protective equipment.
WARNING
Risk of injury from objects falling and being ejected!
Falling and ejected objects during operation can lead to serious
injury or death.
•
Take appropriate protective measures to secure the danger
zone.
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.