Assembly
34
08.00 | PRG | Assembly and Operating Manual | en | 389325
4.3.7 Mounting programmable MMS 22-PI2 magnetic switch
NOTE
The sensor can be used only for sizes 26–64
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2),
Setting dimensions for magnetic
Ø
Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
Ø
Secure the sensor (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Adjust sensor (1), see sensor assembly and operating manual.