5.4.11 Mounting analog MMS 22-A magnetic switch
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2),
Setting dimensions for magnetic
Sizes 40, 64, 80, 100, 125, 160, 200
Ø
Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
Ø
Secure the sensor (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Adjust sensor (1), see sensor assembly and operating manual.
Sizes 50, 200
During the monitoring, the first and last 15% of the nominal stroke
will not produce a change in the analog signal. It is therefore not
possible to monitor the end positions. If you have questions,
please contact SCHUNK.
Size
Stroke 1
Stroke 2
100%
15%
100%
15%
PGN-plus-P 50
4 mm
0.6 mm
2 mm
0.3 mm
PGN-plus-P 200
25 mm 3.75 mm 14 mm
2.1 mm