5.4.3 Switch-off hysteresis for magnetic switches
Sensors MMS 22, MMS-P 22, MMS 22-PI1 and MMS 22-PI2
The smallest detectable difference in stroke is defined in the
following table:
The smallest detectable difference in stroke based on the nominal stroke
For grippers with X mm
nominal stroke per jaw
Min. query range per jaw/
min. queried stroke difference per jaw
X ≤ 5 mm
30% of the nominal stroke per jaw
X > 5 mm to X ≤ 10 mm
20% of the nominal stroke per jaw
X > 10 mm
10% of the nominal stroke per jaw
Example:
Product with 7 mm nominal stroke per jaw
7 mm * 20% = 1.4 mm