![SCHUNK PGN-plus-P Assembly And Operating Manual Download Page 25](http://html1.mh-extra.com/html/schunk/pgn-plus-p/pgn-plus-p_assembly-and-operating-manual_1215988025.webp)
Assembly
10.00 | PGN-plus-P | Assembly- and Operating Manual | en | 389753
25
Item Mounting
PGN-plus-P
160
200
240
300
380
1
Thread in the main air
connections
G1/8 G1/8 G1/8 G1/4 G1/4
Max. depth of engagement
from locating surface [mm]
7
7
7
12
12
2
Thread in the air purge
connection
M5
M5
M5
M5
M5
Max. depth of engagement
from locating surface [mm]
6
6
6
6
6
Air purge connection
The air purge is used in order to make it more difficult for dirt and
dust to penetrate into the product and the guiding areas. With the
dust-tight variant (SD), it is necessary to use the air purge
connection in order to achieve the specified protection class.
5.3 Attaching additional structure
NOTE
With the dust-tight variant (SD), no additional structure can be
attached.
Gripper with additional structure
1
Gripper
4
Centering sleeve
2
Additional structure
5
Gripper fingers
3
Workpiece
For supporting things like workpieces, an additional structure can
be attached to the gripper.