Setting the sensor in "Standard mode"
1. Turn the sensor 1 (1) into the groove (2).
OR: Slide the sensor 1 (1) into the groove (2) until the sensor 1
(1) stops at the T-nut (3).
2. Secure the sensor 1 (1) using the set-screw (4).
Tightening torque: 10 Ncm
3. Adjust sensor 1 (1), see sensor assembly and operating
manual.
4. Repeat steps for sensor 2.
Alternatively for size 20-45, except MPZ 25-AS and MPZ 45:
Setting the sensor in "Optimum mode"
1. Put product in the position in which it is to be set.
2. Hold teaching tool to the sensor 1 (1) until the sensor flashes.
3. Slide sensor 1 (1) into the groove (2), until the sensor 1 flashes
rapidly.
✓
The optimum position is displayed.
4. Secure the sensor 1 (1) using the set-screw (4).
Tightening torque: 10 Ncm
5. Hold teaching tool to the sensor 1 (1) to confirm the position.
✓
The sensor 1 (1) has been taught in.
6. Repeat steps for sensor 2.