Assembly
1. Check the evenness of the mounting surface,
.
2. Only open the required air connections (main connection or
3. Connect the product via the hose-free direct connection.
✓
Use O-rings from the accessory pack.
✓
Seal main air connections which are not required with
locking screws.
4. OR: Connect compressed air lines to the main air
connections,
✓
Screw in air connections (plug connections).
OR: Screw on throttle valve in order to be able to perform
sufficient throttling and/or damping.
5. Screw the product to the machine/system,
.
✓
If necessary, use appropriate connection elements (adapter
plates).
✓
Observe the maximal tightening torque, admissible screw-in
depth and, if necessary, strength class.
6. Secure the gripper fingers to the base jaws,
.
7. Connect the sensor, see assembly and operating manual of the
sensor.
8. Mount the sensor,
21
09.00 | MPZ | Assembly- and Operating Manual | en | 389218