Assembly
04.00 | GSM-R | Assembly and Operating Manual | en | 389106
25
5.3.3 Settings for magnetic switch
NOTE
The installation dimensions shown only apply if the clamping
position of the sensor is not specified by a T-nut.
Installation dimensions for MMS-P
GSM Type
Dimension l
1
Dimension l
2
Dimension l
3
GSM-R 16
27.4
18.5
13.5
GSM-R 16-AS
27.4
18.5
13.5
GSM-R 20
31.7
22.8
17.8
GSM-R 20-AS
31.7
22.8
17.8
GSM-R 25
37.4
28.5
23.5
GSM-R 25-AS
37.4
28.5
23.5
GSM-R 32
45.3
36.4
31.4
GSM-R 32-AS
45.3
36.4
31.4
GSM-R 40
47.7
38.8
33.8
GSM-R 40-AS
47.7
38.8
33.8
5.3.4 Switch-off hysteresis for magnetic switch MMS-P 22
The smallest detectable difference in stroke is defined in the
following table:
The smallest detectable difference in stroke based on the nominal stroke
For grippers with X mm
nominal stroke per jaw
Min. query range per jaw/
min. queried stroke difference per jaw
X ≤ 5 mm
30% of the nominal stroke per jaw
X > 5 mm to X ≤ 10 mm 20% of the nominal stroke per jaw
X > 10 mm