Troubleshooting
02.00 | EMH | Assembly and Operating Manual | en | 1393220
27
7.4 Workpiece is detached from the product
Possible cause
Corrective action
Product is not performing the
magnetization process at all or not
correctly.
Check the product, lines and connections for
damage.
Check the activation time and correct if necessary.
Before activation, the magnetic surface must lie
completely against the workpiece.
Check the type (ramp) and duration commands and
correct if necessary,
The holding force is not sufficient.
Check the magnetic surface and contact surface of
the workpiece for air gaps and clean if necessary. If
required, change product positioning on the
workpiece.
Select a higher holding force level and repeat the
magnetization process if necessary,
21].
Check that the workpiece complies with the
technical data,
14].
7.5 Demagnetization was not performed correctly.
Possible cause
Corrective action
Workpiece has excessive residual
magnetism and does not detach
properly.
Perform the demagnetization process once again.
Check the lines and connections for errors and
damage. Ensure that the voltage supply is correct.