Assembly
11.00 | EGN | Assembly and Operating Manual | en | 389056
37
5.4 Air purge connection for dust-tight (SD) variant
Item Mounting
EGN
80
100
160
1
Thread in air purge
connection
M4
M5
M5
Maximum depth of
engagement [mm]
(from locating surface)
6
CAUTION
Property damage due to incorrect assembly!
If the dust-tight (SD) variant is operated without air purge,
neither the function nor permanent tightness can be guaranteed.
This can result in damage to the product.
•
Connect the air purge to the air purge connection prior to
starting-up the product.
The air purge is connected to the air purge connection via a
pneumatic line. The air purge pressure should be between 0.2 and
0.5 bar.
The air purge serves to compensate for changing volumes within
the gripper during the gripping motion. This ensures that no
vacuum is created in the interior of the gripper and therefore no
dirt is drawn into the gripper.