Assembly
26
11.00 | EGN | Assembly and Operating Manual | en | 389056
5 Assembly
5.1 Assembling and connecting
DANGER
Risk of fatal injury due to electric current!
Touching live parts possess an immediate risk of fatal injury by
electrocution.
•
Prior to commencing work, restore the regulator to a de-
energized state.
✓
Disconnect the logic and motor voltages.
•
Wait until the intermediate circuit voltage has dropped to a
residual voltage of less than 10 V.
✓
LED "UMOT" goes out.
✓
Check "supply voltage" between U
Mot
and GND on the
terminal strip.
CAUTION
Material damage due to mechanical forces!
If the cable, which is fixed to the product, or the plug is exposed
to mechanical forces (e. g. turn or bend), this may lead to a cable
break.
•
Fasten the plug so to the product, that the plug is always in
the quite same position to the gripper and is no subjected to
mechanical stress.
NOTE
See Assembly and Operating Manual "ECM Controller" for
instructions on the electrical connection of the product to the
ECM controller.