Technical data
20
01.00 | EGM | Assembly and Operating Manual | en | 389539
Designation
EGM B-Q
70-1x2
70-1x4
70-2x2
Dimension X x Y x Z [mm]
210 x
115 x 61
370 x
115 x 61
210 x
195 x 61
Weight [kg]
9
25
15
Magnetic surface [cm
2
]
98
196
Number of poles
2
4
Load capacity * for horizontal
magnetic surface [kg]
120
296
290
Load capacity * for vertical
magnetic surface [kg]
48
118
115
Minimum workpiece thickness [mm]
14
18
Max. activations/minute [RPM]
15
10
Increased product temperature **
at 5 / 15 activations per minute [°C]
15 / 40
24 / 60
Current input on activation/
deactivation [A]
6.4
12.3
Max. permissible product
temperature [° C]
+80
Ambient temperature [°C]
Min.
Max.
+5
+50
Air humidity [%]
Min.
Max.
30
80
Noise emission [dB(A)]
≤ 70
IP protection class
54
Permissible controller variant
ECG-C, ECG-W, ECG-R
Permissible controller size
ECG 02
Max. number EGM per controller
9
4
5
* Full load capacity can only be reached under ideal conditions
(material, workpiece density, surface, etc.). In case of
questions on dimensioning of load capacity, contact SCHUNK.
** Increased product temperature tested on material 1.0037
with 20 mm workpiece thickness, ground surface and
complete coverage of the magnetic surface.