Technical data
18
01.00 | EGM | Assembly and Operating Manual | en | 389539
3.4 Basic data EGM M-L
Designation
EGM M-L
08-1-FX 15-1-FX 30-1-FX
Dimension X x Y x Z [mm]
98 x
56 x 58
105 x
47 x 79
96 x
66 x 71
Cable length [cm]
30
30
30
Weight [kg]
1
2.1
3.1
Magnetic surface [cm
2
]
12
22.5
36.9
Number of poles
2
Load capacity * for horizontal
magnetic surface [kg]
10
22
60
Load capacity * for vertical
magnetic surface [kg]
4
9
24
Minimum workpiece thickness [mm]
3
5
10
Max. activations/minute [RPM]
16
16
12
Increased product temperature **
at 5 / 15 activations per minute [°C]
18 / 39
15 / 40
22 / 49
Current input on activation/
deactivation [A]
3.7
2.6
2.2
Max. permissible product
temperature [° C]
+80
Ambient temperature [°C]
Min.
Max.
+5
+50
Air humidity [%]
Min.
Max.
30
80
Noise emission [dB(A)]
≤ 70
IP protection class
54
Permissible controller variant
ECG-C,
ECG-W
ECG-C, ECG-W,
ECG-R
Permissible controller size
ECG 01
ECG 02
ECG 02
Max. number EGM per controller
23
17
32
* Full load capacity can only be reached under ideal conditions
(material, workpiece density, surface, etc.). In case of
questions on dimensioning of load capacity, contact SCHUNK.
** Increased product temperature tested on material 1.0037
with 20 mm workpiece thickness, ground surface and
complete coverage of the magnetic surface.