Item  ID no. 

Quantity  Designation 

Wearing 
part? 

Note 

27 

9942114 

Spacer sleeves M3, self-retaining   

 

28 

9660090 

Screw DIN EN ISO 4762 M3 x 20   

 

29 

9942468 

Flange socket, 4-pin M8 

 

 

30 

9942494 

Screw plug M5 

 

only for 
5516948 

30 

9937198 

Screw plug M8 

 

only for 
5516949 

30 

9905303 

Screw plug M12 

 

only for 
5516950 

31 

9905303 

Screw plug M12 

 

 

32 

9942469 

Plug-in jumper 

 

Enclosed pack 

33 

9659005 

Locking screw M5 

 

Enclosed pack 

34 

9611227 

O-ring Ø5x1 

 

Enclosed pack 

35 

9611112 

O-ring Ø4x1.5 

 

Enclosed pack 

36 

9939378 

Guide sleeve dia. Ø8x5.35 

 

Enclosed pack 

37 

9939380 

Guide sleeve dia. Ø12x6.65 

 

Enclosed pack 

38 

9941732 

Cable plug M16 

 

Enclosed pack 

39 

9937198 

Screw plug M8 

 

 

40 

9611076 

O-ring Ø12x1 

 

 

41 

9611300 

O-ring Ø3.5x1 

 

 

43 

9942127 

O-ring Ø41 x 1.5 

 

 

44 

9942470 

O-ring Ø71.5 x 1.0 

 

 

45 

9611063 

O-ring Ø6 x 1 

 

 

46 

9611227 

O-ring Ø5 x 1 

 

 

47 

9907474 

O-ring Ø22x1 

 

 

48 

9941190 

Nut M18x0.75 

 

 

 
 
EDF for SRU 50/60

 

– M5/M8/M12 – ID. Nos. 

5516955 

Item  ID no. 

Quantity  Designation 

Wearing 
part? 

Note 

5516208 

Distributor plate EDF 50/60 

 

 

5516206 

Cover plate EDF 50/60 

 

 

5516238 

Flange EDF 50/60 

 

 

5516414 

Plate EDF 50/60 

 

 

9939230 

O-ring Ø27x1.5 

 

 

5516958 

Cover plate 2 EDF 50/60 

 

 

5516694 

Reducing sleeve EDF 50/60 

 

 

9664501 

Countersunk screw M3 x 8 

 

 

9942019 

20 

Set screw M4 x 4 PA-coated 

 

 

10 

9942020 

Set screw M5 x 4 PA-coated 

 

 

11 

9662006 

Screw DIN EN ISO 4762 M3 x 8 

 

 

12 

9938292 

Countersunk screw M3 x 6 

 

 

13 

9907495 

Screw DIN EN ISO 4762 M3 x 30   

 

14 

9660095 

Screws DIN EN ISO 4762 M10x30   

 

15 

9662502 

Oval head screw M3 x 6 

 

 

16 

9939379 

Guide sleeves Ø10 x 6,65 

 

 

17 

9939382 

Guide sleeves Ø16 x 8,6 

 

 

18 

9936169 

Screw-in connection, straight G1/8   

 

Summary of Contents for EDF 20

Page 1: ...complete satisfaction SCHUNK products are inspiring Our detailed assembly and operation manual will support you Do you have further questions You may contact us at any time even after purchase You ca...

Page 2: ...ELIVERY 5 4 TECHNICAL DATA 5 4 1 CONNECTION OPTIONS 5 4 2 DATA 5 5 ASSEMBLY AND INSTALLATION 6 5 1 INSTALLATION OF THE ELECTRICAL CABLE FEED THROUGH IN THE SRU ROTARY ACTUATOR 6 5 2 CABLE ASSIGNMENTS...

Page 3: ...irective the accident prevention regulations the VDE guidelines or the safety and installation instructions are not observed All personnel who are responsible for installation commissioning and servic...

Page 4: ...gs can have parts that are under spring tension Therefore special care is necessary when dismantling such a unit In the event of emergency shut down the rotary unit can still move due to a drop in pre...

Page 5: ...3 x 14 EDF 57 M 3 x 14 and the following small components O rings for air feed through 4 x for EDF 20 25 35 8 x for EDF 40 50 60 O rings for direct air connections 6 for SRU without center position 7...

Page 6: ...IMPORTANT Damage to the cable connection of the adapter plate is possible Do not pull on the cable too strongly 7 Now fasten the distributor plate on the pinion with the two screws item 28 8 Check the...

Page 7: ...ctor for BUS connection SRU 40 8 x M5 1 x M12 Connector for proximity switch connection Connector for BUS connection SRU 40 8 x M8 1 x M12 Connector for proximity switch connection Connector for BUS c...

Page 8: ...V common 24 V 24 V 24 V J not used not used not used not used K not used not used not used not used L not used not used not used not used M not used not used not used not used Shield SHD SHD SHD SHD 5...

Page 9: ...H TxD 5 SHD SHD SHD Refer to the technical documentation for the Schunk sensors for the assignment of the housing sockets on the output side for sensor connection 5 5 Assembly of SRU with EDF Assembli...

Page 10: ...pplied connector M8 Standard setting sensors If direct air supply is used the set screws must be removed and the hose connections at the side air connections replaced by sealing plugs enclosed pack Pl...

Page 11: ...nance and servicing Check the cable for damage and abrasion after 1 million swivel movements Remove the flange by undoing the screws The flange inside and the cable spiral must be lubricated again by...

Page 12: ...Assembly and Operating Manual Electrical Feed Through for SRU Type EDF 12 Print date 01 07 2010 Figure 6 Exploded view of the EDF for SRU 40 60...

Page 13: ...es 12 x 6 65 18 9936167 4 Screw in connection straight M5 19 9941379 1 Spiral round cable for EDF 20 35 20 9941714 4 Flange socket 3 pin M5 only for 5516940 5516942 20 9341033 4 Flange socket 3 pin M8...

Page 14: ...07495 2 Screw DIN EN ISO 4762 M3 x 30 14 9660014 2 Screws DIN EN ISO 4762 M5 x 30 15 9662502 2 Oval head screw M3 x 6 16 9939378 2 Guide sleeves 8 x 5 35 17 9939380 2 Guide sleeves 12 x 6 65 18 993616...

Page 15: ...Cover plate 2 EDF 50 60 7 5516695 1 Reducing sleeve EDF 40 8 96640501 2 Countersunk screw M3x8 9 9942019 20 Set screw M4 x 4 PA coated 10 9942020 11 Set screw M5 x 4 PA coated 11 9662006 4 Screw DIN E...

Page 16: ...O ring 12x1 41 9611300 8 O ring 3 5x1 43 9942127 1 O ring 41 x 1 5 44 9942470 1 O ring 71 5 x 1 0 45 9611063 8 O ring 6 x 1 46 9611227 3 O ring 5 x 1 47 9907474 1 O ring 22x1 48 9941190 1 Nut M18x0 7...

Page 17: ...4 Spacer sleeves M3 self retaining 28 9660003 2 Screw DIN EN ISO 4762 M3 x 16 29 9942468 1 Flange socket 4 pin M8 30 9942494 8 Screw plug M5 only for 5516941 5516953 30 9937198 8 Screw plug M8 only fo...

Page 18: ...ct Shanghai 200032 Tel 86 21 64433177 Fax 86 21 64431922 info cn schunk com www cn schunk com FRANCE SCHUNK Intec SARL Parc d Activit s des Trois Noyers 15 Avenue James de Rothschild Ferri res en Brie...

Page 19: ...7665 info mx schunk com www mx schunk com PORTUGAL Sales Representative Victor Marques Tel 34 937 556 020 Fax 34 937 908 692 Mobil 351 963 786 445 info pt schunk com www pt schunk com SPAIN SCHUNK In...

Page 20: ...Assembly and Operating Manual Electrical Feed Through for SRU Type EDF 20 Print date 01 07 2010...