Assembly and Operating Manual
Electrical Feed-Through for SRU Type EDF
5
Print date 01.07.2010
3. Scope of delivery
The EDF is normally supplied together with an SRU unit and then bears the product name “SRU
...-
EDF...”. In this case, parts of the scope of delivery described below are installed in the overall
unit.
The scope of delivery of the EDF consists of:
-
Distributor plate with spiral cable, integrated circuit board and housing sockets
-
Connecting flange
-
2 securing screws
EDF 20: M 2 x 12
– EDF 40: M 3 x 14
EDF 45: M 3 x 14
– EDF 57: M 3 x 14
and the following small components:
-
O-rings for air feed-through
-
4 x for EDF 20 / 25 / 35
– 8 x for EDF 40 / 50 / 60
-
O-rings for direct air connections
-
6 for SRU without center position
– 7 x for SRU with center position
-
Locking screw M5 / G1/8”
-
4 x for EDF 20 / 25 / 35
– 8 x for EDF 40 / 50 / 60
-
2 guide sleeves for screwing on SRU with EDF
-
2 guide sleeves for screwing on adapter plate
-
Jumpers for switching sensors to BUS feed-through
-
Cable plug M16 (for self-assembly)
4. Technical data
4.1. Connection options:
Output side:
-
4x/8x sensor M5 / M8 / M12 (3-pin) or alternatively:
-
1x BUS M12 (5-pin)
Screw connection side:
-
Supply cable: M16 (12-pin)
4.2. Data
U
max
: 60 V
I
max
(per wire): 2 A
Transfer rate for Profibus: max. 1.5 Mbaud