background image

Assembly and Operating Manual 

Electrical Feed-Through for SRU Type EDF 

Print date 01.07.2010 

1. Safety

1.1. Symbol key 

You will find this symbol wherever 

hazards for persons

 or 

damage to the product 

are possible. 

This symbol indicates 

important information 

on the product or its handling. 

1.2. Appropriate use 

The unit must only be used within the scope of its technical data. Appropriate use also includes 
compliance with the conditions the manufacturer has specified for commissioning, assembly, 
operation, the environment and maintenance. Using the unit with disregard to even a minor 
specification will be deemed inappropriate use. The manufacturer assumes no liability for any 
injury or damage resulting from inappropriate use. 

1.3. 

Safety notes

 

There are potential risks associated with the unit, for example if: 
the unit is improperly used, installed or serviced. 
the unit is used other than for the intended purpose. 
the EC Machine Directive, the accident prevention regulations, the VDE guidelines or the 
safety and installation instructions are not observed. 

All personnel who are responsible for installation, commissioning and servicing must have 
read and understood the entire operating manual, in particular the chapter on »Safety«. It is 
recommended to have this confirmed in writing. 

Installation and dismantling, mounting of the proximity switches, connections and 
commissioning may be carried out only by authorized personnel. 

Work procedures that impair the correct functioning and operational safety of the product 
are prohibited. 

Do not move any parts by hand when the unit is connected to the power supply. 

Do not reach into the open mechanical parts and the area of motion of the rotary unit. 

The power supply cables must be removed for assembly, modification, maintenance and 
adjustment of the unit. 

Carry out all maintenance, modifications or attachments outside of the danger zone. 

During installation, connection, adjusting, commissioning and testing, measures must be 
taken to prevent the risk of inadvertent activation of the unit by the fitter or other persons. 

Summary of Contents for EDF 20

Page 1: ...complete satisfaction SCHUNK products are inspiring Our detailed assembly and operation manual will support you Do you have further questions You may contact us at any time even after purchase You ca...

Page 2: ...ELIVERY 5 4 TECHNICAL DATA 5 4 1 CONNECTION OPTIONS 5 4 2 DATA 5 5 ASSEMBLY AND INSTALLATION 6 5 1 INSTALLATION OF THE ELECTRICAL CABLE FEED THROUGH IN THE SRU ROTARY ACTUATOR 6 5 2 CABLE ASSIGNMENTS...

Page 3: ...irective the accident prevention regulations the VDE guidelines or the safety and installation instructions are not observed All personnel who are responsible for installation commissioning and servic...

Page 4: ...gs can have parts that are under spring tension Therefore special care is necessary when dismantling such a unit In the event of emergency shut down the rotary unit can still move due to a drop in pre...

Page 5: ...3 x 14 EDF 57 M 3 x 14 and the following small components O rings for air feed through 4 x for EDF 20 25 35 8 x for EDF 40 50 60 O rings for direct air connections 6 for SRU without center position 7...

Page 6: ...IMPORTANT Damage to the cable connection of the adapter plate is possible Do not pull on the cable too strongly 7 Now fasten the distributor plate on the pinion with the two screws item 28 8 Check the...

Page 7: ...ctor for BUS connection SRU 40 8 x M5 1 x M12 Connector for proximity switch connection Connector for BUS connection SRU 40 8 x M8 1 x M12 Connector for proximity switch connection Connector for BUS c...

Page 8: ...V common 24 V 24 V 24 V J not used not used not used not used K not used not used not used not used L not used not used not used not used M not used not used not used not used Shield SHD SHD SHD SHD 5...

Page 9: ...H TxD 5 SHD SHD SHD Refer to the technical documentation for the Schunk sensors for the assignment of the housing sockets on the output side for sensor connection 5 5 Assembly of SRU with EDF Assembli...

Page 10: ...pplied connector M8 Standard setting sensors If direct air supply is used the set screws must be removed and the hose connections at the side air connections replaced by sealing plugs enclosed pack Pl...

Page 11: ...nance and servicing Check the cable for damage and abrasion after 1 million swivel movements Remove the flange by undoing the screws The flange inside and the cable spiral must be lubricated again by...

Page 12: ...Assembly and Operating Manual Electrical Feed Through for SRU Type EDF 12 Print date 01 07 2010 Figure 6 Exploded view of the EDF for SRU 40 60...

Page 13: ...es 12 x 6 65 18 9936167 4 Screw in connection straight M5 19 9941379 1 Spiral round cable for EDF 20 35 20 9941714 4 Flange socket 3 pin M5 only for 5516940 5516942 20 9341033 4 Flange socket 3 pin M8...

Page 14: ...07495 2 Screw DIN EN ISO 4762 M3 x 30 14 9660014 2 Screws DIN EN ISO 4762 M5 x 30 15 9662502 2 Oval head screw M3 x 6 16 9939378 2 Guide sleeves 8 x 5 35 17 9939380 2 Guide sleeves 12 x 6 65 18 993616...

Page 15: ...Cover plate 2 EDF 50 60 7 5516695 1 Reducing sleeve EDF 40 8 96640501 2 Countersunk screw M3x8 9 9942019 20 Set screw M4 x 4 PA coated 10 9942020 11 Set screw M5 x 4 PA coated 11 9662006 4 Screw DIN E...

Page 16: ...O ring 12x1 41 9611300 8 O ring 3 5x1 43 9942127 1 O ring 41 x 1 5 44 9942470 1 O ring 71 5 x 1 0 45 9611063 8 O ring 6 x 1 46 9611227 3 O ring 5 x 1 47 9907474 1 O ring 22x1 48 9941190 1 Nut M18x0 7...

Page 17: ...4 Spacer sleeves M3 self retaining 28 9660003 2 Screw DIN EN ISO 4762 M3 x 16 29 9942468 1 Flange socket 4 pin M8 30 9942494 8 Screw plug M5 only for 5516941 5516953 30 9937198 8 Screw plug M8 only fo...

Page 18: ...ct Shanghai 200032 Tel 86 21 64433177 Fax 86 21 64431922 info cn schunk com www cn schunk com FRANCE SCHUNK Intec SARL Parc d Activit s des Trois Noyers 15 Avenue James de Rothschild Ferri res en Brie...

Page 19: ...7665 info mx schunk com www mx schunk com PORTUGAL Sales Representative Victor Marques Tel 34 937 556 020 Fax 34 937 908 692 Mobil 351 963 786 445 info pt schunk com www pt schunk com SPAIN SCHUNK In...

Page 20: ...Assembly and Operating Manual Electrical Feed Through for SRU Type EDF 20 Print date 01 07 2010...

Reviews: