Maintenance and care
28
03.00 | CLM | Assembly and operating manual | en | 389015
7 Maintenance and care
CAUTION
The following recommendations apply to intended use in
accordance with the specified operating parameters, operating
conditions and settings .
Maintenance work
Maintenance interval
Inspect the shock absorbers
Regularly
Replace shock absorber
every 2 million cycles
Check seals
Regularly
Replace seals
As required
The seals are included in the seal kit
SCHUNK recommends the lubricants listed.
Grease
Isoflex-Topas NCA 52 or equivalent